EasyManua.ls Logo

Smeg CA61VM - Page 10

Smeg CA61VM
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Instructions for the installer
41
3.3 Burner and nozzle characteristics table (90 cm model)
Burner
Rated
heating
capacity
(kW)
LIQUID GAS G30/G31 30/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
capacity
(W)
Capacity
g/h G30
Capacity
g/h G31
Auxiliary 1 50 30 350 73 71
Semi-rapid 1.8 65 33 450 131 129
Rapid 3 85 45 800 218 214
Triple crown (4) 3.2 91 65 1500 233 229
Triple crown (8) 3.5 94 65 1500 255 250
Fish kettle 1.9 68 45 800 138 136
Oven 3.2 87 50 900 233 229
Maxi oven 5.2 110 59 1300 378 372
Grill 2.9 87 // // 211 207
Maxi grill 4.0 100 // // 291 286
Burner
Rated
heating
capacity
(kW)
CITY GAS G110 8 mbar
Nozzle diameter
1/100 mm
Reduced capacity
(W)
Auxiliary 1 145 350
Semi-rapid 1.8 185 450
Rapid 3 260 800
Triple crown 3.5 290 1200
Fish kettle 1.9 190 800
Gas G110 cannot be used in gas oven models.
The values for city gas refer to appliances in category III 1a2H3+.
Burner
Rated
heating
capacity
(kW)
NATURAL GAS G20 20 mbar
Nozzle diameter
1/100 mm
Reduced capacity
(W)
Auxiliary 1 72 350
Semi-rapid 1.8 97 450
Rapid 3 115 800
Triple crown (4) 3.5 133 1500
Triple crown (8) 3.5 140 1500
Fish kettle 1.9 94 800
Oven 3.2 130 850
Maxi oven 5.2 164 1200
Grill 2.9 130 //
Maxi grill 4.0 150 //