Installation
42
The nozzles not provided are available at Authorised Service Centres.
7 LPG G30/31 AUX SR UR-3c
Rated heating capacity (kW) 1.05 1.8 3.5
Nozzle diameter (1/100 mm) 50 65 94
Pre-chamber (printed on nozzle) - - -
Reduced flow rate (W) 400 500 1600
Rated flow rate G30 (g/h) 76 131 255
Rated flow rate G31 (g/h) 75 129 250
8 LPG G30/31 AUX SR UR-3c
Rated heating capacity (kW) 1.1 1.8 3.5
Nozzle diameter (1/100 mm) 50 65 91
Pre-chamber (printed on nozzle) - - -
Reduced flow rate (W) 450 550 1600
Rated flow rate G30 (g/h) 80 131 255
Rated flow rate G31 (g/h) 79 129 250
9 LPG G30/31 AUX SR UR-3c
Rated heating capacity (kW) 1.05 1.8 3.5
Nozzle diameter (1/100 mm) 43 58 75
Pre-chamber (printed on nozzle) (H2) (M) (F4)
Reduced flow rate (W) 400 500 1600
Rated flow rate G30 (g/h) 76 131 255
Rated flow rate G31 (g/h) 75 129 250
10 Town Gas G110 AUX SR UR-3c
Rated heating capacity (kW) 1.05 1.8 3.4
Nozzle diameter (1/100 mm) 145 185 315
Pre-chamber (printed on nozzle) 8 2 13
Reduced flow rate (W) 400 500 1200