EasyManua.ls Logo

Smeg SR975BGHD - Page 20

Smeg SR975BGHD
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Instructions for the installer
22
9.4 Adjustment for natural gas G20 - G20/G25
The cooker hob is preset for natural gas G20 (2H) - G20/G25 (2E+)
at a pressure of 20 mbar - 20/25 mbar . To reset the appliance
for operation with this type of gas, carry out the same steps as described in “9.2
Adjustment for LPG”, but select the nozzles and adjust the primary air for natural
gas as indicated in the table below and in "9.5 Primary air adjustment”. After the
adjustments have been carried out, restore the seals with sealing wax or
equivalent material.
Burner
Rated
heating
capacity
(kW)
Natural gas G20/G25 20/25 mbar
G20 20 mbar
Nozzle diameter
1/100 mm
Reduced capacity
(W)
Auxiliary (1) 1.1 76 400
Semi-rapid (2) 1.7 95 450
Medium rapid (3) 2.6 115 650
Large Rapid (4) 3.0 126 750
Ultra-rapid (5) 3.3 132 1400
Double crown
Internal (6) 1.1 76 400
External (6) 3.9 145 1200
9.5 Primary air adjustment
Refers to distance X”inmm.
BURNER
G30/G31
28/37 mbar
G20/G25
20/25
mbar
G20 20 mbar
G25
20 mbar
G30/G31
50 mbar
Auxiliary (1) 2.0 1.5 1.5 1.5
Semi-rapid (2) 2.0 1.5 1.5 2.0
Medium rapid (3) 1.5 1.0 1.0 1.0
Large Rapid (4) 3.0 2.0 1.5 1.5
Ultra-rapid (5) 3.0 1.8 1.8 2.5
Double crown
Internal (6) 4.0 2.0 2.0 3.0
External (6) 10.0 3.0 4.0 10.0
To identify the burners on your hob, refer to the drawings in “9.7 Arrangement of the burners on the
cooking hob”.
BE
BE
BE
BE