Note: If any of following issues persist, return wrench to an authorized Snap-on repair center.
Issue
Possible Cause
Resolution
Wrench does not turn on when
POWER button pressed
Dead/No batteries
Replace batteries
Software glitch
Cycle power using end-cap
Torque reading out of spec
Calibration required
Recalibrate
Incorrect head length entered
Enter correct offset head length
Wrench did not retain settings
while batteries were removed
Batteries removed before
settings were saved in non-
volatile memory.
Clear data, re-enter settings and
press and hold POWER button
to power down wrench before
removing batteries
Torque or angle displayed while
no torque applied
Torque or angle zeroed while
torque applied
Place wrench on stable surface
with no torque applied and press
POWER button to re-zero
wrench
Low battery
Press ENTER
button to
continue using wrench and
replace batteries soon
Dead battery
Press
POWER
button to turn
off wrench and replace batteries
Torque applied while zeroing
Remove torque and re-zero
Wrench over torqued
Recalibrate
Wrench improperly calibrated
Recalibrate
Torque sensor failure
Return to Snap-on Repair Center
Wrench moving during zeroing
Place wrench on stable surface
Gyro unstable
Return to Snap-on Repair Center
POWER
button pressed
during angle zeroing (Aborted
zeroing to access menus)
Place wrench on stable surface
and press POWER button to re-
zero
Over 125% of full scale torque
applied
Cycle power using
POWER
button and recalibrate
Wrench rotated too fast during
angle measurement
Place wrench on stable surface
and press POWER button to re-
zero
Calibration interval exceeded
or invalid date entered with
calibration interval enabled
Calibrate wrench or press
ENTER to continue. Disable
calibration interval if not
required.
Memory failure
Clear data memory
Torque uncalibrated
Calibrate torque

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Snap-On TECHANGLE STEEL ATECH4RS600 and is the answer not in the manual?

Snap-On TECHANGLE STEEL ATECH4RS600 Specifications

General IconGeneral
BrandSnap-On
ModelTECHANGLE STEEL ATECH4RS600
CategoryPower Tool
LanguageEnglish

Related product manuals