Transmit Code ID Character (2Dh)
R : 00 00 05 C7 04 00 2D S1 S2
W : 00 00 07 C6 04 00 FF 2D 01 S1 S2
Symbol Code ID Character
W : 00 00 07 C6 04 00 FF 2D 02 S1 S2
AIM Code ID Character
W : 00 00 07 C6 04 00 FF 2D 00 S1 S2
*None
Prefix/Suffix Values (68h/69h/6Ah)
R : 00 00 05 C7 04 00 69 S1 S2
W : 00 00 07 C6 04 00 FF 69 00 S1 S2
Scan Prefix
(Triple Setting , input 3 digits , Range : 000~255.)
R : 00 00 05 C7 04 00 68 S1 S2
W : 00 00 07 C6 04 00 FF 68 0D S1 S2
Scan Suffix 1
(Triple Setting , input 3 digits , Range : 000~255.)
R : 00 00 05 C7 04 00 6A S1 S2
W : 00 00 07 C6 04 00 FF 6A 0A S1 S2
Scan Suffix 2
(Triple Setting , input 3 digits , Range : 000~255.)
Scan Data Transmission Format (EBh)
R : 00 00 05 C7 04 00 EB S1 S2
W : 00 00 07 C6 04 00 FF EB 00 S1 S2
*Data As Is