800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3200 A
3 P 4 P 3 P 4 P 3 P 4 P 3 P 4 P 3 P 4 P 3 P 4 P 3 P 4 P
in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in mm
C
15.39 391 15.39 391 15.39 391 15.39 391 15.39 391 15.39 391 15.39 391 15.39 391 523 20.59 523 20.59 523 20.59 523 20.59 523 20.59 523 20.59
F
19.84 504 22.99 584 19.84 504 22.99 584 19.84 504 22.99 584 23.46 596 28.19 716 23.46 596 28.19 716 23.46 596 28.19 716 23.46 596 28.19 716
M
10.04 255 13.19 335 10.04 255 13.19 335 10.04 255 13.19 335 13.66 347 18.39 467 13.66 347 18.39 467 13.66 347 18.39 467 13.66 347 18.39 467
T
3.15 80 3.15 80 3.15 80 3.15 80 3.15 80 3.15 80 4.72 120 4.72 120 4.72 120 4.72 120 4.72 120 4.72 120 4.72 120 4.72 120
X
1.87 47.5 1.87 47.5 1.87 47.5 1.87 47.5 1.87 47.5 1.87 47.5 2.09 53 2.09 53 2.11 53,5 2.11 53,5 2.11 53,5 2.11 53,5 2.11 53,5 2.11 53,5
90°
90°
I
II
0
POWER
AUT
Ø 4 ... 8mm
PROG
OK
AUT
READY
TEST ON LOAD
TEST OFF LOAD
ATyS g
Un
Auto Conf
5
1
10
14
5
1
10
13
0
1
5
10
20
60
0
1
5
10
20
60
G:
H:
E:
F:
REMOTE CONTROL
A: 3 Ph
B: 1 Ph
C: Neutral
D: Neutral
ATyS
Un N°
PP / PN
1: 220 / 127
2: 380 / 220
3: 400 / 230
4: 415 / 240
5: 480 / 277
6: 208 / 120
7: 220 / 127
8: 230 / 132
9: 240 / 138
10: 380 / 220
11: 400 / 230
12: 415 / 240
13: 480 / 277
5
6
7
8
9
10
11
12
13
14
15
16
18
20
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:
3
3
4
4
5
5
6
6
7
7
8
8
9
10
N°: Δ
U
Δ
F
%
XXX
50 Hz60 Hz
XXXXXXXX
Motorised Changeover Switch
1600A Ref : 95054160
5.43
138
5.91
150
X
T
Fix. M
F
C
C
Fix. 9.84
250
11.02
280
11.02
280
0.83
21
0.83
21
0.35
9
0.49
12.5
0.33
8,5
0.62
15,75
0.62
15,75
0.20
5
0.20
5
0.63x0.43
16x11
ø 0.35
ø 9
ø 0.59
ø 15
0.59
15
ø 0.49
ø 12,5
0.59
15
1.12
28,5
1.12
28,5
0.33
8,5
1.97
50
2.36
60
3.54
90
1.30
33
1.18
30
1.18
30
1.77
45
1.77
45
0.98
25
0.98
25
1.30
33
0.39
10
1250 A
1
2
301 3022
312313 314315 316317 63A64A 24 14 04 13
CONTROL OUTPUTS
1
2
2
1
3
3x
Ø 4-8 mm
Contactor logicImpulse logic
order I
position I
order 0
position 0
order II
position II
STEP 6A
Automatic Operation
Ensure that the emergency handle is not
inserted in the product and turn the mode
selector to the AUT position.
LED “Power” Green: ON
LED Manuel/Default: OFF
Non contractual document.
Subject to change without notice.CORPORATE HQ CONTACT: SOCOMEC SAS 1-4 RUE DE WESTHOUSE - 67235 BENFELD, FRANCE - WWW.SOCOMEC.COM
STEP 3
Dimensions in./mm.
800 A to 1000 A
2000 A to 3200 A
800 A to 1600 A
1600 A
to 3200 A
ATyS Voltage
Sensing and
Power supply
Kit excludes the
need for fuses
F1 & F2.
Manual Operation
STEP 6B
Imp. ≥60ms maintened
To enable control, close contact 312 with 317.
To force the product to 0 position/OFF bridge the contact
313 with 317. For contactor logic bridge contact 316
with 317. To operate: close the contact corresponding
to the desired position.
STEP 5
Check
Whilst in manual mode, check
the wiring and if ok power up the
product.
LED “Power” Green: ON
LED Manuel/Defaut Red
(Productnot Available): ON
STEP 4
Ensure that the product is in Manual Mode.
CONTROL / COMMAND Terminals
Power Supply Terminal
Remove the Top cover to access and connect the terminal - Replace the cover before putting in service.
STEP 6C
Padlocking Mode
(as standard : in position O)
Connect the product with a cable of
section of 1,5 to 2,5 mm
2
.
Screw M3 - Tightening torque:
min.: 0.5 Nm - max.: 0.6 Nm
min.: 4.43 lbin - max.: 5.31 lbin