socomec ATyS s - User Manual

socomec ATyS s
140 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
www.socomec.com
ATySp
Automatic Transfer Switching Equipment
EN
INSTRUCTION
MANUAL

Table of Contents

Other manuals for socomec ATyS s

Questions and Answers

  • T
    Travis MartinAug 22, 2025
    What to do if it is not possible to manually operate the switch of Socomec Industrial Electrical?
    • M
      michaelschneiderAug 22, 2025
      If it is not possible to manually operate the switch, verify the following: * That the front selector switch position is on the Manual position. * That the product is not padlocked. * The rotation direction of the handle. * Apply a sufficient progressive action in the direction as indicated on the handle.
  • P
    Pamela SolisAug 25, 2025
    What to check if nothing happens following a loss of the priority source on Socomec Industrial Electrical (application Main-Gen)?
    • J
      Joel NguyenAug 25, 2025
      If nothing happens following a loss of the priority source (application Main-Gen), you should: * Check the setting of 1FT. After 1FT has counted down 71-72-74 should change state. * Check the status of the "gen set start" contact (contact 71-73-74) after 1FT countdown. * Check the wiring from the "gen set start" contact (71-72-74) to the generating set controller.
  • D
    David JohnsonAug 26, 2025
    What to do if socomec Switch ATyS S does not respond to remote orders?
    • C
      Cathy WheelerAug 26, 2025
      If the socomec ATyS S switch doesn't respond to remote commands, first, put the product into manual mode and switch to the zero position using the emergency handle. Then, reset by switching from manual to auto in the zero position. Also, check that the AUX Supply voltage is within limits and confirm that the remote signals are being received.
  • W
    william39Aug 27, 2025
    Why socomec ATyS s electrical operation does not correspond to expected behavior?
    • L
      Lisa CollinsAug 28, 2025
      If the electrical operation of your socomec Switch does not match the expected behavior, verify the selected control logic wiring (impulse or contactor). For Impulse, ensure >60ms with these connections: 314 – 317 (Switch to position II), 315 – 317 (Switch to position I), 316 – 317 (Switch to position 0). For Maintained, check the bridge between 316 – 317 for Contactor Logic (Return to zero).
  • B
    Brenda KingAug 29, 2025
    How to manually operate socomec ATyS s Switch?
    • M
      Michael IrwinAug 29, 2025
      To manually operate the socomec switch, ensure the front selector switch is in the Manual position. Also, check that the product is not padlocked and verify the rotation direction of the handle.
  • H
    hopkinsvictoriaAug 31, 2025
    How to troubleshoot socomec Switch ATyS S that does not operate electrically?
    • L
      lhorneAug 31, 2025
      If the socomec ATyS S switch isn't operating electrically, check the power supply on terminals 101 to 402, ensuring it's within the correct voltage range: 12Vdc (9 – 15Vdc), 24/48Vdc (17 – 62Vdc), or 230Vac (160 – 310Vac). Also, verify that the front selector switch is in the (AUT) position and check the contact terminal and contact signals between 314 and 317, which should be normally open contacts with priority to signals I & II.
  • P
    Patricia EverettSep 2, 2025
    Why is it impossible to padlock socomec ATyS s Switch?
    • P
      Paul DaughertySep 2, 2025
      If you cannot padlock the socomec Switch, first verify that the front selector switch is in the padlocking position. Secondly, ensure that the emergency handle for manual operation is not inserted into the ATyS S manual slot. Finally, confirm that the ATyS S is in the 0 position, as padlocking is only possible in this position with the emergency manual operation handle removed.
  • M
    Megan WatersSep 5, 2025
    Why does the fault LED turn on in Socomec Industrial Electrical (ATS Controller)?
    • M
      Mr. Anthony MoranSep 5, 2025
      The fault LED on the ATS Controller might be on because an external fault/alarm condition is active through one of the ATyS configurable inputs. This is normal and can be reset by opening the associated contact input. To attempt to solve the problem, switch the ATyS p from AUT to Manual and back to AUT.
  • B
    Brett MejiaSep 7, 2025
    Why is the SOURCE availability indicator not illuminating on my Socomec Industrial Electrical device?
    • A
      Amanda OdonnellSep 7, 2025
      If the SOURCE availability indicator does not illuminate when the source is available, try the following: * Press the "LED test" button and ensure that the corresponding LED’s illuminate. * Check in programming mode that the nominal voltage value (by default set to 400V), the nominal frequency value and the network configuration correspond to the network and modify if necessary. * Check the voltage and frequency thresholds and hysteresis for this source, in the Volt and Frequency menus and modify if necessary.
  • M
    Mark MedinaSep 9, 2025
    What to do if electrical operation does not correspond to external order I,O,II on Socomec Industrial Electrical?
    • W
      wendywelchSep 9, 2025
      If the electrical operation does not correspond to external order I,O,II, you should: * Verify the selected control logic wiring (impulse or contactor). * Verify the connector connections.

Summary

General Safety Instructions

Quick Start

Quick Start ATyS p Frame B3 to B5 (125 A to 630 A)

Provides step-by-step instructions for the initial setup of ATyS p models from Frame B3 to B5.

Quick Start ATyS p Frame B6 to B8 (800 A to 3200 A)

Details the initial setup process for ATyS p models from Frame B6 to B8.

General Overview

ATS Control Module Interface

Details the interface of the ATS control module, including LEDs, LCD, and keypad.

Environmental

Covers the environmental requirements, including IP rating, operating conditions, and storage.

ATyS p Accessories Available

Lists and briefly describes the accessories available for the ATyS p product.

Installation

Product Dimensions

Provides detailed dimensional specifications for different ATyS p frames (B3 to B8).

Mounting Orientation

Explains the recommended and allowed mounting orientations for the ATyS p.

Assembly of Customer Mounted Accessories

Details the process for assembling various customer-mounted accessories for the ATyS p.

Connections

Power Circuits

Covers the power connection aspects, including cable/bar connections and cross-sections.

Networks and Power Connection Possibilities

Explains different network types and their corresponding connection possibilities.

Control Circuits

Details the wiring and connections for control circuits, including typical diagrams.

Voltage Sensing and Power Supply Kit

Explains the voltage sensing and power supply kit installation and standard configuration.

Operating Modes

Manual Operation

Describes manual operation, including emergency manual operation and padlocking.

Electrical Operation

Explains electrical operation, including dual power supply and voltage sensing inputs.

Programming

Programming with Easy Config Software

Details how to program the ATyS p using the Easy Config software.

Programming with the ATyS p Keypad

Explains how to program the ATyS p using its built-in keypad.

The LCD Display

Display Mode Navigation and Visualisation

Describes how to navigate and visualize information on the LCD display.

Putting the ATyS P into Auto Operation

Trouble Shooting Guide

Events Display

Explains how to interpret event messages displayed on the LCD screen for troubleshooting.

Annexe I. Programming with the ATyS p Keypad

Annexe I - 3. Keypad Programming - General Information

General guidance on keypad programming, including navigation and password entry.

Annexe I - 10. Timers Menu - Keypad Navigation

Details the timer settings for various operational sequences and delays.

Annexe I - 11. I;O Menu - Keypad Navigation

Explains the Input/Output menu for configuring and managing inputs and outputs.

Annexe I - 11.1. Programmable Inputs

Details the internal and external programmable inputs available for the ATyS p.

Annexe I - 11.3. Programmable Outputs

Lists and defines the available programmable outputs for the ATyS p.

Annexe I - 12. Communication Menu - Keypad Navigation

Details the communication settings menu for configuring network parameters.

Annexe II. MODBUS Communication Address and Designation Details

Annexe II - 17. Setup Timer

Provides MODBUS addresses for setting various timers.

Annexe II - 18. Setup Threshold for Upstream Voltages

Details MODBUS addresses for setting upstream voltage thresholds.

Annexe II - 19. Setup User’s Power Threshold

Explains MODBUS settings for user-defined power thresholds.

Annexe II - 20. Setup Network

Provides MODBUS addresses for network setup parameters.

Annexe II - 21. Setup Input;Output

Details MODBUS addresses for setting up inputs and outputs.

socomec ATyS s Specifications

General IconGeneral
Product CategoryTransfer Switch
Protection DegreeIP20
Operating ModeManual
Electrical Durability1, 000 cycles
Control Voltage24 V DC