www.socomec.com
ATySp
Automatic Transfer Switching Equipment
EN
INSTRUCTION
MANUAL

Other manuals for socomec ATyS p

Question and Answer IconNeed help?

Do you have a question about the socomec ATyS p and is the answer not in the manual?

socomec ATyS p Specifications

General IconGeneral
ControlAutomatic
StandardsIEC 60947-6-1
Rated Insulation Voltage Ui690 VAC
Rated Frequency50/60 Hz
TypeAutomatic Transfer Switch
Number of Poles4P
MountingDIN rail mounting
Product functionAutomatic source transfer
Rated Operational Voltage Ue400 V AC
Mechanical Durability10, 000 operations
Electrical Durability1, 000 operations at rated current
Protection DegreeIP20

Summary

GENERAL SAFETY INSTRUCTIONS

INTRODUCTION

THE ATYS FAMILY PRODUCT RANGE

The ATyS Range Key Features

Highlights the key features of the ATyS range of products.

QUICK START

Quick Start ATyS p Frame B3 to B5 (125A to 630A)

Quick start guide for ATyS p models B3 to B5 (125A to 630A).

Quick Start ATyS p Frame B6 to B8 (2000A to 3200A)

Quick start guide for ATyS p models B6 to B8 (2000A to 3200A).

GENERAL OVERVIEW

Product introduction

Introduces the ATyS p product and labels its main parts.

Product identification

Details the identification labels and electrical characteristics of the ATyS p.

ATS Control module interface

Explains the ATS control module, its LEDs, and display screen functions.

Environmental

Details the environmental requirements for the ATyS p product.

IP Rating

Specifies the IP rating for the ATyS p motorization control unit and power section.

Operating Conditions

Covers operating conditions such as temperature, humidity, and altitude.

Storage Conditions

Outlines storage conditions including temperature and duration.

Volume and shipping weights by reference ATyS p

Provides volume and shipping weight details for ATyS p by frame size and rating.

CE marking

Lists the European directives and electromagnetic compatibility standards the ATyS p complies with.

Lead free process

States ATyS p compliance with the European directive for RoHS.

WEEE

Confirms ATyS p's compliance with the 2002/96/CE directive.

EMC standard

Details ATyS p compliance with EMC standards, listing requirements.

ATyS p Accessories

Lists and describes various accessories available for the ATyS p.

INSTALLATION

Product dimensions

Provides detailed product dimensions for ATyS p frames B3 to B5.

DIMENSIONS: FRAME B3 TO B5 (125A TO 630A)

Detailed dimensions for ATyS p frames B3 to B5, covering various ratings and poles.

DIMENSIONS: FRAME B6 & B7 (800A TO 1600A)

Detailed dimensions for ATyS p frames B6 & B7 (800A to 1600A).

DIMENSIONS: FRAME B8 (2000A TO 3200A)

Detailed dimensions for ATyS p frames B8 (2000A to 3200A).

Mounting orientation

Shows recommended mounting orientations for different ATyS p ranges.

Assembly of customer mounted accessories

Instructions for assembling customer-mounted accessories for ATyS p.

Terminal shrouds

Details on terminal shrouds for ATyS p, covering mounting and installation.

Terminal screens

Describes terminal screens for protection of terminals or connection parts.

Bridging bar installation

Instructions for installing bridging bars on ATyS p switches.

Copper bar connection kits (2000A to 3200A : FRAME B8)

Details copper bar connection kits for ATyS p Frame B8 (2000A-3200A).

Incoming copper bar connection kit assembly

Assembly instructions for incoming copper bar connection kits.

Outgoing bridge connection assembly

Assembly instructions for outgoing bridge connection assemblies.

External Power supply (400VAC - 230VAC)

Details the connection of external power supplies (400VAC - 230VAC) for ATyS p.

Raised mounting spacers

Information on raised mounting spacers for ATyS p frames B3, B4 and B5.

Padlocking key interlocks

Describes padlocking key interlocks for electrical and backup control in position 0.

Additional auxiliary contacts

Information on fitting additional auxiliary contacts for ATyS p.

ATyS p Optional module installation

Instructions for installing optional modules like RS485, Ethernet, I/O, etc.

CONNECTIONS

Power circuits

Details power circuit connections, including cable/bar connections and terminals.

Cable or bar connections

Explains how to make cable or bar connections for ATyS p power circuits.

Power connection terminals

Details the power connection terminals used in ATyS p.

Power connection cross-section

Specifies recommended cable cross-sections for ATyS p power connections.

Standard Connection Priority Source Supply On Switch I

Describes the standard connection for priority source supply on Switch I.

Specific Connection Priority Source Supply On Switch II

Details specific connection configurations for priority source supply on Switch II.

Networks and Power Connection possibilities

Outlines various network and power connection possibilities for ATyS p.

Type of networks

Lists and illustrates different types of networks supported by ATyS p.

Metering and sensing details

Provides details on metering and sensing configurations for ATyS p.

Control circuits

Explains the control circuit wiring for ATyS p.

Typical ATyS p wiring

Shows typical wiring diagrams for ATyS p control circuits.

ATyS p input and output wiring

Wiring details for ATyS p motorisation and ATS control modules.

Motorisation module wiring

Wiring diagram for the ATyS p motorisation module.

ATS control module wiring

Wiring diagram for the ATyS p ATS control module.

ATyS p connection (optional Module) I/O Wiring Connections

Wiring connections for optional I/O modules in ATyS p.

Terminal denomination, description and characteristics

Lists terminal denominations, descriptions, and characteristics for ATyS p.

Voltage sensing and power supply kit

Details the voltage sensing and power supply kit for ATyS p.

Standard configuration

Describes the standard configuration possibilities for the sensing and power supply kit.

Sensing and power supply kit installation (4 wire configuration)

Installation steps for the sensing and power supply kit in a 4-wire configuration.

Sensing kit wiring diagram

Wiring diagrams for sensing kits, covering standard and specific configurations.

Sensing kit wiring diagram (specific)

Specific wiring diagrams for sensing kits, detailing network and supply wiring.

OPERATING MODES

MANUAL OPERATION

Details how to operate the ATyS p in manual mode.

Emergency manual operation

Instructions for performing emergency manual operation of the ATyS p.

Padlocking

Information on padlocking the ATyS p in various positions.

Electrical operation

Covers electrical operations of the ATyS p, including dual power supply and voltage sensing.

Dual power supply

Details the dual power supply connections for the ATyS p.

Voltage sensing inputs

Explains the voltage sensing inputs for ATyS p, including network configurations.

Fixed inputs

Describes the fixed inputs on the ATyS p motorisation module.

Description

Provides descriptions for each fixed input and their functions.

Remote control logic

Explains the remote control logic options for ATyS p.

Programmable inputs

Details the configuration of programmable inputs for ATyS p.

Fixed outputs - Dry contacts

Describes the fixed outputs (dry contacts) on the ATyS p.

ATyS p Product available output (motorisation)

Explains the product available output function for the ATyS p motorisation module.

Programmable dry contact output

Details the configuration of programmable dry contact outputs for ATyS p.

PROGRAMMING

Programming with Easy Config software

Step-by-step guide for programming the ATyS p using the Easy Config software.

Download and Install Easy Config Software

Instructions for downloading and installing the Easy Config software.

Programming with the ATyS p keypad

Guide to programming the ATyS p directly using its keypad.

THE LCD DISPLAY

Presentation

Overview of the ATyS p LCD display and its information presentation.

Display mode navigation and visualisation

Details how to navigate and visualize information on the ATyS p LCD display.

LOCAL / REMOTE CONTROL (POSITIONS I – O – II)

AUTOMATIC MODE

MANUAL & AUTOMATIC MODE / MAINS RESTORATION CONDITIONS

Describes manual/automatic modes and mains restoration conditions.

PRIORITY SOURCE LOSS SEQUENCE M-G

Explains the priority source loss sequence for Main-Generator applications.

PRIORITY SOURCE LOSS AND RESTORATION SEQUENCE M-M

Details the priority source loss and restoration sequence for Main-Main applications.

PRIORITY SOURCE AUTOMATIC RESTORATION SEQUENCE

Describes the automatic restoration sequence for priority sources.

PRIORITY SOURCE RESTORATION SEQUENCE M-G

Outlines the priority source restoration sequence for Main-Generator applications.

TEST MODES

TEST OFF LOAD

Details the Test Off Load functionality and its activation.

Test On Load

Explains the Test On Load functionality for ATyS p.

Engine exerciser (Periodic TEST)

Describes the engine exerciser function for periodic testing.

COMMUNICATION

GENERAL INFORMATION

Provides general information on communication via RS485 connection.

MODBUS® PROTOCOL

Explains the MODBUS protocol used by ATyS p for communication.

PUTTING THE ATYS P INTO AUTO OPERATION

CHARACTERISTICS

Characteristics according to IEC 60947-3

Details characteristics according to IEC 60947-3 standard.

Rated operational currents Ie (A) according to IEC 60947-6-1

Lists rated operational currents according to IEC 60947-6-1.

PREVENTIVE MAINTENANCE

TROUBLE SHOOTING GUIDE

ACCESSORIES

Terminal shrouds

Details terminal shrouds for protection against direct contact.

Terminal screens

Describes terminal screens for protection of terminals or connection parts.

Bridging bars

Information on bridging bars for power terminals on the top or bottom side of the switch.

Copper bar connection kits

Details copper bar connection kits for ATyS p.

Solid neutral

Describes the solid neutral connection kit for ATyS p.

Autotransformer 400/230 VAC

Information on the autotransformer for applications without neutral.

DC power supply

Details the DC power supply option for ATyS p.

Voltage sensing and power supply kit

Information on the voltage sensing and power supply kit.

Voltage relay

Describes the voltage relay for monitoring ATyS p power supply.

Door protective surround

Describes the door protective surround for ATyS p.

Auxiliary contacts (additional)

Information on additional auxiliary contacts for ATyS p.

Mounting spacers

Details mounting spacers for increasing terminal clearance.

3 position padlocking (I - O - II)

Information on 3-position padlocking for ATyS p.

RONIS Key interlocking system

Describes the RONIS key interlocking system for ATyS p.

Current transformers

Information on current transformers for ATyS p.

Plug-in optional modules

Details optional plug-in modules for ATyS p communication and I/O.

Remote interface

Describes the remote interface for ATyS p, including D10 and D20.

Connection cable for remote interface

Details the connection cable for the remote interface.

Auto/Manual key selector

Describes the auto/manual key selector for ATyS p.

SPARE PARTS

Electronic module

Spare electronic modules for ATyS d, t, g, and p.

Motorisation module

Spare motorisation modules for ATyS r, d, t, g, and p.

Power section

Spare power sections for ATyS r, d, t, g, or p.

ATYS FAMILY: ORDERING INFORMATION

Annexe I. PROGRAMMING WITH EASY CONFIG SOFTWARE

Annexe I - 1. Getting started – the main functional keys

Introduces the main functional keys in the Easy Config software.

Annexe I - 2. Selecting the ATyS p product

Steps for selecting the ATyS p product within the Easy Config software.

Annexe I - 3. Status and control screen

Describes the status and control screen in Easy Config software.

Annexe I - 4. Setting screen

Details the setting screens within the Easy Config software for ATyS p configuration.

Annexe I - 4.1. Setting screen 1 – configuration details

Configuration details for Setting Screen 1 in Easy Config software.

Annexe I - 5. Power management screen

Explains the power management screen for setting ratings and load shedding.

Annexe I - 6. Timers screen

Details the timers screens available in Easy Config software.

Annexe I - 6.1. Timers screen 1

Configuration details for Timers Screen 1 in Easy Config software.

Annexe I - 6.3. Timers screen 2 – configuration details

Configuration details for Timers Screen 2 in Easy Config software.

Annexe I - 6.4. Timers screen 3

Details Timers Screen 3, available for Main-Gen applications.

Annexe I - 7. Input and output configuration screen

Describes the input and output configuration screen in Easy Config software.

Annexe I - 7.1. Programmable inputs – configuration details

Configuration details for programmable inputs in Easy Config software.

Annexe I - 7.2. Programmable outputs – configuration details

Configuration details for programmable outputs in Easy Config software.

Annexe I - 8. Engine exerciser screen

Explains the engine exerciser screen for scheduling tests.

Annexe I - 8.1. Engine exerciser – configuration details

Configuration details for the engine exerciser in Easy Config software.

Annexe I - 9. Saving the configured settings

Instructions on how to save configured settings in Easy Config software.

Annexe I - 10. Event recording screen

Describes the event recording screen in Easy Config software.

Annexe I - 11. Super User added functionality

Details added functionality accessible by Super Users in Easy Config software.

Annexe I - 11.1. Control panel

Explains the control panel features for Super Users.

Annexe I - 11.1.2. Remote position switching I - 0 - II

How to switch remote positions I-0-II via software for Super Users.

Annexe I - 11.1.3. Remote command orders

How to send remote command orders to the ATyS p via software.

Annexe I - 11.1.4. Remote set and reset of alarms and faults

How to remotely set and reset alarms and faults on the ATyS p.

Annexe I - 11.1.5. Remote real time clock setting

How to remotely set the real-time clock of the ATyS p.

Annexe I - 11.2. Reset screen - Super User added functionality

Using the reset screen for Super User added functionality in ATyS p.

Annexe II. PROGRAMMING WITH THE ATYS P KEYPAD

Annexe II - 1. Getting starteded - Software Version

Information about the software version displayed after product reset.

Annexe II - 2. Keypad Operational Modes

Details the operational modes accessible via the ATyS p keypad.

Annexe II - 2.1. VISUALISATION

How to view measured values and parameter timers via the keypad.

Annexe II - 2.2. OPERATION

Performing test sequences or electrical control of the position via keypad.

Annexe II - 2.3. PROGRAMMING

Parameter configuration and programming via the keypad.

Annexe II - 3. Keypad programming - general information

General information and navigation for keypad programming.

Annexe II - 4. Configuration navigation screen

Navigating the configuration screens via the ATyS p keypad.

Annexe II - 5. Parameter modifications

How to modify parameters using the ATyS p keypad, with an example.

Annexe II - 6. Setup menu – keypad navigation

Navigating the setup menu using the ATyS p keypad.

Annexe II - 6.1. Phase rotation check:

How to perform a phase rotation check using the ATyS p keypad.

Annexe II - 7. Voltage levels menu – keypad navigation

Navigating the voltage levels menu via the ATyS p keypad.

Annexe II - 8. Frequency levels menu – keypad navigation

Navigating the frequency levels menu via the ATyS p keypad.

Annexe II - 9. Power levels menu – keypad navigation

Navigating the power levels menu via the ATyS p keypad.

Annexe II - 10. Timers menu – keypad navigation

Navigating the timers menu via the ATyS p keypad.

Annexe II - 11. I/O Menu – Keypad navigation

Navigating the I/O menu using the ATyS p keypad.

Annexe II - 11.1. Programmable inputs

Details on programmable inputs for ATyS p, including external options.

Annexe II - 11.2. Operation of the EON function:

Explains the operation of the EON function based on timer settings.

Annexe II - 11.3. Programmable outputs

Describes the programmable outputs available for ATyS p.

Annexe II - 11.4. Operation of load shedding before transfer

Explains the operation of load shedding before transfer.

Annexe II - 12. Communication menu – keypad navigation

Navigating the communication settings menu via the ATyS p keypad.

Annexe II - 13. Date and Time – keypad navigation

Navigating the date and time settings menu via the ATyS p keypad.

Annexe III. MODBUS® Communication address and designation details

Annexe III - 1. Metrology Affected by Current and Voltage Transformers

Lists metrology data affected by current and voltage transformers.

Annexe III - 2. Energy

Details energy measurements for ATyS p.

Annexe III - 3. Metrology not affected by current and voltage transformers

Lists metrology data not affected by current and voltage transformers.

Annexe III - 4. Input/Output state

States of inputs and outputs for ATyS p.

Annexe III - 5. Network setting

Details network setting parameters for ATyS p.

Annexe III - 6. Hour/Date setting

Information on setting the hour and date for ATyS p.

Annexe III - 7. Ethernet module interface

Describes the Ethernet module interface for ATyS p.

Annexe III - 8. Action system

Details the action system codes for ATyS p.

Annexe III - 9. Status

Lists the status codes and their descriptions for ATyS p.

Annexe III - 10. Engine exerciser - custom time range status

Status of custom time ranges for the engine exerciser.

Annexe III - 11. Measurement table (no CT/VT affected)

Measurement table for ATyS p, excluding CT/VT affected data.

Annexe III - 12. Energies and time meters

Details energies and time meters for ATyS p.

Annexe III - 13. Timers state

Lists the states of various timers in the ATyS p.

Annexe III - 14. Option module state

Describes the state of optional modules installed on ATyS p.

Annexe III - 15. Commands

Lists commands and their corresponding codes for ATyS p.

Annexe III - 16. User commands

Lists user commands and their descriptions for ATyS p.

Annexe III - 17. Setup timer

Instructions for setting timers for ATyS p.

Annexe III - 18. Setup threshold for upstream Voltages.

Setting thresholds for upstream voltages in ATyS p.

Annexe III - 19. Setup user’s power threshold

Setting user power thresholds for ATyS p.

Annexe III - 20. Setup network

Configuring network settings for ATyS p.

Annexe III - 21. Setup Input/Output

Configuring input and output functions for ATyS p.

Annexe III - 22. Communication settings

Details communication settings for ATyS p.

Annexe III - 23. Product counters

Details the product counters for ATyS p.

Annexe III - 24. Output set

Configuration options for ATyS p outputs.

Annexe III - 25. Input state

Status of input states for ATyS p.

Annexe III - 26. Setup pulse and 0/4-20mA option modules

Setup for pulse and 0/4-20mA option modules for ATyS p.

Annexe III - 27. Setup custom time

Setting custom time parameters for ATyS p.

Annexe III - 28.1. Detailed events

Detailed information on events recorded by ATyS p.

Related product manuals