page 12 of 24
mod. JUMBO 13 - man. rev. 00
Manual of SODASTREAM Professional SRL Unipersonale. No reproduction allowed without previous authorization by
the owner.
Switch on the cooler using the main switch placed on the side only after
connecting the tubes, opening the water, the pressure reducer if installed and
the CO
2
(to prevent the carbonation pump to prevent it from idling).
The backlit switch indicated the cooler is on.
If using JUMBO 13 for the first time, it is necessary to wait 3 hours before the cooler
is ready to fully work.
During this time the cooler is functioning, but with limited performance.
Follow the above-described procedure even after prolonged periods of
inactivity.
Regulate the pressure of water from the mains
Warning When regulating pressure, verify the new flow dispensing a small
quantity of water. For an optimum performance of the cooler regulate the
pressure between 2 and 3 bars
Regulate the pressure of CO2
Warning Open the pressure reducer only after completing the installation
procedures
Water carbonation can be regulated intervening on the knob of the pressure
reducer screwed on the cylinder.
Warning When modifying the CO pressure, the corresponding carbonation
level will be reached after dispensing 0,5 liters of cold sparkling water
Warning. Regulate the pressure at least 0.5 bar over the value of inlet water
pressure operating on the COknob. The CO pressure can be regulated up
to a maximum of 5 bars
When water carbonation progressively decreases it is necessary to replace
the COcylinder.