mod. JUMBO 13 - man. rev. 00
Manual of SODASTREAM Professional SRL Unipersonale. No reproduction allowed without previous authorization by
the owner.
Documentation reserved to technicians
Warning: All the repairs described below must be performed by qualified
technicians only
Warning: Always cut off power before working on live parts
The system does not start
Check the electrical power
system
The system does not cool
the water
Room temperature too high
Make sure sufficient air
circulation is guaranteed
Contact a specialized
technician
The motorized fan does not
work
Replace the motorized fan
The motorized fan does not
work
Check the electrical system.
Replace the motorized fan
The compressor is stopped
but the motorized fan is
running
The compressor “clickson”
circuit breaker triggered
Wait until the compressor
restarts. If the problem
persists, contact a specialized
technician.
The carbonation pump
emits an annoying noise
Inlet water pressure is too low
Verify the pressure of the
water mains using a post-filter
manometer (not less than 2
bars).
Verify the filters are not
clogged, if they are they need
to be replaced.