mod. JUMBO 13 - man. rev. 00
Manual of SODASTREAM Professional SRL Unipersonale. No reproduction allowed without previous authorization by
the owner.
Verify the little filter of the
WATER BLOCK is not
clogged with lime or other.
Carbonation is low or
barely noticeable
Insufficient inlet Co2 pressure
Replace CO₂ cylinder if
exhausted
Air cumulated in the
carbonator
Briefly let air out of the
carbonator pulling the ring on
the vent valve on top of the
carbonator
When pressing the
sparkling water button only
CO₂ comes out
Motor of the carbonation
pump does not work because
the pump is blocked (ex. by
limestone)
Level control box failure
Replace level control box
Slightly lower the thermostat
and wait
When pressing the
sparkling water button,
sprays of sparkling water
come out
Carbonation pump does not
work
Carbonation pump starts
and stops too rapidly and
frequently
Inverted connections between
control box and level probes
Connect control box and level
probes correctly
Excessive pressure in the
carbonator or in the water
mains
Check fitting are tightened
Reduce pressure in the water
mains
No dispensing of cold still
and cold sparkling water
Carbonation pump does not
start
Carbonator is full of water
Verify water and CO₂
pressure
Defective carbonator probes
Replace carbonator probes