SOFAR 15~24KTLX-G3 User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd.
- 64 -
PV cable.
ID06
OVRT
OVRT faulty
There are internal faults of inverter,
turn OFF the DC switch, wait for
5 minutes, then turn ON the DC
switch. Check whether the fault is
rectified. If no, please contact
technical support.
ID07
LVRT
LVRT faulty
ID08
IslandFault
Islanding faulty
ID09
GridOVPInstant1
Grid
instantaneous
voltage too high 1
ID10
GridOVPInstant2
Grid
instantaneous
voltage too high 2
ID11
VGridLineFault
Grid Line voltage
Faulty
ID12
InvOVP
Inverter
overvolatge
ID17
HwADFaultIGrid
The grid current
sampling error
ID18
HwADFaultDCI
The DCI sampling
error
ID19
HwADFaultVGrid
(DC)
Grid voltage
sampling faulty
DC side
ID20
HwADFaultVGrid
(AC)
Grid voltage
sampling faulty
AC side
ID21
GFCIDeviceFault(
DC)
Current leakage
samplingDC
side
There are internal faults of inverter,
turn OFF the DC switch, wait for
5 minutes, then turn ON the DC
switch. Check whether the fault is
ID22
GFCIDeviceFault(
Current leakage