EasyManua.ls Logo

Sofar solar 3K-6KTLM-G3 - User Manual

Sofar solar 3K-6KTLM-G3
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Shenzhen SOFAR SOLAR Co., Ltd.
Solar Grid-tied Inverter
Product Model: SOFAR 3K~6KTLM-G3
User manual

Questions and Answers

  • R
    rsotoAug 5, 2025
    What to do if Sofar solar 3K-6KTLM-G3 Inverter shows GridOVP alarm frequently?
    • A
      Alyssa LewisAug 5, 2025
      If the GridOVP alarm occurs occasionally, it could be due to temporary electric grid abnormalities. The inverter should automatically return to normal once the grid stabilizes. However, if the alarm is frequent, verify that the grid voltage and frequency are within the acceptable range. If they are, inspect the AC circuit breaker and AC wiring of the inverter. If the grid voltage/frequency is outside the acceptable range and the AC wiring is correct, contact technical support to adjust the grid over-voltage, under-voltage, over-frequency, and under-frequency protection points, but only after getting approval from your local electrical grid operator.
  • K
    Kyle SmithAug 9, 2025
    How to prevent OverTempDerating on Sofar solar Inverter?
    • M
      Mary BeltranAug 10, 2025
      To prevent OverTempDerating on your Sofar solar Inverter, ensure it's installed away from direct sunlight. Place it in a cool, well-ventilated area. Also, make sure the inverter is mounted vertically and that the ambient temperature stays below the inverter's maximum temperature limit.
  • J
    John CastanedaAug 13, 2025
    What to do if Sofar solar 3K-6KTLM-G3 Inverter displays GFCI error?
    • D
      dylanterryAug 14, 2025
      If your Sofar solar Inverter is showing a GFCI error, switch it OFF and wait for 5 minutes. Then, switch it back ON. If the problem persists, it indicates internal faults of the inverter, and you should contact technical support for assistance.
  • A
    Amy JohnsonAug 18, 2025
    What to do if Sofar solar 3K-6KTLM-G3 shows BMS OVP error?
    • N
      Nicole NelsonAug 18, 2025
      If your Sofar solar Inverter displays a BMS OVP error, close the inverter and lithium battery, wait 5 minutes, and then reopen them. If the problem continues, it may indicate an internal failure of the lithium battery, and you should contact technical support.
  • S
    Susan QuinnAug 22, 2025
    How to fix TempFault_Bat error on Sofar solar 3K-6KTLM-G3 Inverter?
    • M
      Ms. Dawn MosleyAug 23, 2025
      To resolve a TempFault_Bat error on your Sofar solar Inverter, ensure the unit is not exposed to direct sunlight. Install the inverter in a cool, well-ventilated location, mount it vertically, and verify that the ambient temperature remains below the inverter's temperature limit.
  • T
    Tamara Neal PhDAug 27, 2025
    What to do if Sofar solar Inverter displays IsoFault error?
    • M
      Michael WilsonAug 27, 2025
      If your Sofar solar Inverter is showing an IsoFault error, check the insulation resistance between the photovoltaic array and ground. If you find a short circuit, repair it immediately.
  • C
    Christopher LeeAug 31, 2025
    How to resolve PvConfigError on Sofar solar 3K-6KTLM-G3 Inverter?
    • S
      Sean ShermanAug 31, 2025
      To resolve a PvConfigError on your Sofar solar Inverter, check the inverter's PV input mode settings (parallel/independent mode). If the settings are incorrect, change the PV input mode accordingly.

Sofar solar 3K-6KTLM-G3 Specifications

General IconGeneral
Model3K-6KTLM-G3
CategoryInverter
Max. DC Voltage600V
Maximum PV Input Voltage600V
Number of MPPTs2
Rated AC Voltage230V
AC Voltage Range180-280V
THDi<3%
Peak Efficiency98.6%
Protection DegreeIP65
CoolingNatural Convection
Max. Input Current per MPPT11A
Power Factor0.8 leading - 0.8 lagging
Operating Temperature Range-25°C to +60°C
CommunicationRS485

Related product manuals