Shenzhen SOFARSOLAR Co., Ltd.
Energy storage integrated inverter
Product Model: HYD 3K~6K-ES
User manual

Questions and Answers

  • A
    Aaron GreenSep 23, 2025
    How to resolve BatUTD error on Sofar solar HYD 3000-ES Inverter?
    • K
      Kristi MahoneySep 23, 2025
      To address a BatUTD error on your Sofar solar Inverter, try to increase the ambient temperature of the battery.
  • M
    Michael DaughertyAug 23, 2025
    What to do if Sofar solar HYD 3000-ES shows GFCI OCP fault frequently?
    • G
      Gregory ScottAug 23, 2025
      If the GFCI OCP fault occurs frequently and lasts a long time on your Sofar solar Inverter, check whether the insulation resistance between the PV array and earth (ground) is too low, and also inspect the insulation conditions of the PV cables.
  • W
    wesley32Aug 25, 2025
    Why does my Sofar solar HYD 3000-ES Inverter show GridOVP?
    • J
      Justin CoxAug 25, 2025
      The GridOVP alarm on your Sofar solar Inverter can occur because the electric grid is occasionally abnormal. The inverter should automatically return to normal operating status when the electric grid returns to normal. If the alarm occurs frequently, check whether the grid voltage/frequency is within the acceptable range. If yes, please check the AC circuit breaker and AC wiring of the inverter.
  • K
    Katie WilliamsAug 27, 2025
    How to fix PVOVP error on Sofar solar HYD 3000-ES?
    • A
      Audrey HermanAug 27, 2025
      The PVOVP error on your Sofar solar Inverter means that too many PV modules are series connected in a PV string. Check whether the PV string voltage (Voc) is higher than the maximum input voltage of the inverter. If it is, adjust the number of series connected PV modules to decrease the PV string voltage to fit the input voltage range of the inverter. The inverter will automatically return to normal status after correcting adjustments.
  • S
    Samantha KnightAug 27, 2025
    How to resolve 'BatCommunication Flag' error on Sofar solar Inverter?
    • Z
      zacharykrauseAug 28, 2025
      To resolve the 'BatCommunication Flag' error on your Sofar solar Inverter: * Make sure the battery you’re using is compatible with the inverter. * Ensure you’ve selected the correct battery type. * Check the communication cable between the battery & the inverter. It’s recommended to use CAN communication. * For PYLONTECH US2000 PLUS battery, and you’re using RS485 communication, the ADD DIP switch should be all down.
  • J
    Joseph CarpenterSep 18, 2025
    How to fix SDfault on Sofar solar HYD 3000-ES?
    • L
      Lisa ParkerSep 18, 2025
      The SDfault (ID98) on your Sofar solar Inverter is normally caused by a loose SD card holder. To fix this, click and take out the SD card, press the SD card holder, and then reinsert the SD card back in.
  • B
    Brian MartinezSep 15, 2025
    What to do if Sofar solar HYD 3000-ES shows OVRT fault?
    • D
      David JordanSep 15, 2025
      If your Sofar solar Inverter is showing an OVRT fault, check whether the grid voltage fluctuates greatly.
  • G
    Gregory WilcoxSep 16, 2025
    What causes IpvUnbalance on Sofar solar HYD 3000-ES and how to fix it?
    • A
      adamsabigailSep 16, 2025
      The IpvUnbalance error on your Sofar solar Inverter can be caused by an incorrect PV input mode setting. Check the PV input mode (parallel mode/ independent mode) setting of the inverter and change it if it’s incorrect.
  • K
    Kyle MoraSep 6, 2025
    How to troubleshoot BatUTC error on Sofar solar HYD 3000-ES?
    • U
      umendozaSep 7, 2025
      To troubleshoot the BatUTC error on your Sofar solar Inverter, try to increase the ambient temperature of the battery.
  • D
    dunnsarahSep 3, 2025
    How to resolve BatOTD error on Sofar solar HYD 3000-ES Inverter?
    • M
      Mr. Brian ColeSep 4, 2025
      To resolve the BatOTD error on your Sofar solar Inverter, make sure the battery is in a well-ventilated place. You can also try to decrease the max discharge (A) or/and max charge (A) to see if the problem is solved.

Sofar solar HYD 3000-ES Specifications

General IconGeneral
ModelHYD 3000-ES
TypeHybrid Inverter
Rated Output Power3000 W
Max. DC Input Power4500 W
Max. DC Voltage600 V
Number of MPPTs2
Max. Input Current per MPPT11 A
Nominal AC Voltage230 V
AC Voltage Range180-280V
Max. AC Output Power3000 W
Max. Output Current13 A
Max Efficiency97.5%
Efficiency97%
Battery Voltage48 V
Max. Charging/Discharging Current50A
Dimensions420 x 370 x 130 mm
Weight12 kg
Cooling MethodNatural Cooling
Protection ClassIP65
CommunicationRS485/WiFi/GPRS/Ethernet
Max. PV Input Power4500 W
Max. PV Input Voltage600 V
Number of MPP Trackers2
Output Voltage230 V
Output Frequency50/60 Hz
Peak Efficiency97.5%
European Efficiency97%
MPPT Efficiency99.9%
Operating Temperature Range-25°C to 60°C