Shenzhen SOFARSOLAR Co., Ltd.
Energy storage integrated inverter
Product Model: HYD 5K~20KTL-3PH
User manual

Questions and Answers

  • K
    Kathleen HendrixSep 15, 2025
    What to do if Sofar solar HYD 8KTL-3PH AC frequency is too high?
    • L
      Lisa MooreSep 16, 2025
      If the AC frequency of your Sofar solar Inverter is too high, please ensure the grid frequency and voltage are within the acceptable range.
  • L
    Loretta PooleAug 25, 2025
    What to do if Sofar solar HYD 8KTL-3PH displays GFCI error?
    • C
      Carla BautistaAug 25, 2025
      If your Sofar solar inverter displays a GFCI error, switch OFF the inverter, wait for 5 minutes, and then switch it ON again to see if the problem is resolved. If the error persists, it may indicate internal faults of the inverter, and you should contact technical support for further assistance.
  • T
    Tammy WilliamsAug 25, 2025
    What to do if Sofar solar Inverter displays TempFault_Bat error?
    • L
      Leonard BennettAug 26, 2025
      If your Sofar solar inverter displays a TempFault_Bat error, ensure that the battery NTC cable is properly connected for Inner BMS battery. Also, make sure the inverter is installed where there is no direct sunlight, in a cool and well-ventilated place. Ensure the inverter is installed vertically and the ambient temperature is below the inverter temperature limit.
  • J
    Juan JosephAug 26, 2025
    Why Sofar solar HYD 8KTL-3PH Inverter shows OverTempDerating?
    • S
      Scott JohnsonAug 27, 2025
      The OverTempDerating error on your Sofar solar inverter indicates it's overheating. To resolve this, ensure the inverter is installed in a cool, well-ventilated area away from direct sunlight. Also, verify that the inverter is mounted vertically and that the ambient temperature is below the inverter's temperature limit.
  • D
    David MartinezSep 16, 2025
    What to do if Sofar solar HYD 8KTL-3PH Inverter displays 'Battery low voltage protection'?
    • G
      Gordon JonesSep 17, 2025
      If your Sofar solar Inverter shows a 'Battery low voltage protection' message, check whether the battery voltage of the inverter is too low.
  • D
    dadamsSep 23, 2025
    What to do if Sofar solar HYD 8KTL-3PH Inverter displays 'Master does not exist or is duplicate'?
    • C
      carloshuberSep 23, 2025
      If your Sofar solar Inverter shows 'Master does not exist or is duplicate', check the parallel mode settings for the inverter and ensure the wiring is correct.
  • D
    Donna SmithSep 8, 2025
    How to fix PvConfigError on Sofar solar HYD 8KTL-3PH Inverter?
    • C
      Charles WaltonSep 8, 2025
      To fix a PvConfigError on your Sofar solar Inverter, check the PV input mode (parallel/independent mode) settings for the inverter and change the PV input mode if needed.
  • S
    Samuel StewartSep 9, 2025
    What to do if Sofar solar HYD 8KTL-3PH shows grid overvoltage?
    • B
      Brittney HillSep 9, 2025
      If your Sofar solar Inverter is showing a grid overvoltage error occasionally, it might be due to temporary grid issues; the inverter should return to normal when the grid stabilizes. However, if this happens frequently, verify that the grid voltage/frequency is within the acceptable range. If it is, inspect the AC circuit breaker and AC wiring of the inverter. If the grid voltage/frequency is outside the acceptable range and the AC wiring is correct, and the alarm persists, you may need to contact technical support to adjust the grid over-voltage, under-voltage, over-frequency, under-frequency protection points, but only after getting approval from your local electrical grid operator.
  • F
    fevansSep 2, 2025
    Why does my Sofar solar HYD 8KTL-3PH Inverter show a BMSCommunicationFault?
    • N
      Nicole ColeSep 2, 2025
      A BMSCommunicationFault on your Sofar solar inverter may occur if your battery is not compatible with the inverter. CAN communication is recommended. Check the communication line or port of the battery and inverter for faults.
  • A
    Adam NguyenAug 31, 2025
    What causes PVOVP error on Sofar solar HYD 8KTL-3PH and how to fix it?
    • K
      Kelsey Smith MDSep 1, 2025
      The PVOVP error on your Sofar solar inverter indicates that the PV series voltage (Voc) is higher than the maximum input voltage of the inverter. To resolve this, check whether the PV series voltage is indeed too high. If it is, adjust the number of PV modules in series to reduce the PV series voltage, ensuring it fits within the input voltage range of the inverter. After making this correction, the inverter should automatically return to its normal state.

Summary

Basic Safety Information

Safety Instructions

General safety guidelines for inverter installation, operation, and maintenance.

Symbols and Signs

Explanation of safety symbols (Danger, Warning, Caution, Attention, Note) used in the manual.

Product Characteristics

Function Characteristics

Details key features like overloading, UPS mode, dual MPP trackers, and efficiency.

Application Modes

Installation

Installation Process

Provides a flowchart outlining the steps for installing the inverter.

Determining the Installation Position

Guides on selecting the appropriate mounting location for the inverter.

Installing the Inverter

Step-by-step guide for mounting the inverter onto the wall.

Electrical Connections

Wire Instructions

Details cable specifications and connection types for battery, PV, and load.

Battery Connection & PV Connection

Explains how to connect the battery and PV input terminals correctly.

AC Load Connection

Guides on connecting the AC load terminal to the inverter.

AC Grid Connection

Provides instructions for connecting the inverter to the AC grid.

Operation (Commission)

Double Check

Lists critical checks to perform before operating the inverter.

First Time Setup (IMPORTANT!)

Step-by-step guide for initial inverter setup and power-on.

Advanced Setting

Covers advanced settings such as battery parameters, anti-reflux, and parallel setup.

Battery Pack Configuration

One Battery Pack Configuration

Details wiring and setup for one battery pack on channel 1, 2, or both.

Troubleshooting

Fault Identification and Shutdown

Procedures for identifying faults, safely shutting down, and checking requirements.

Event List and Fault Codes

Information on viewing event lists and understanding fault codes (e.g., Grid overvoltage, GFCI Fault).

Technical Data

Sofar solar HYD 8KTL-3PH Specifications

General IconGeneral
Rated Power8000W
Max. DC Voltage1100V
Start Voltage180 V
Number of MPPT2
Rated AC Power8000W
Rated AC Voltage400 V
THDi<3%
Power Factor>0.99 (Adjustable ±0.8 leading to ±0.8 lagging)
Rated Grid Frequency50/60 Hz
Output Frequency50/60 Hz
THD<3%
DC SwitchYes
Protection ClassIP65
Operating Temperature Range-25°C to +60°C
CoolingNatural convection
Weight25 kg
TypeHybrid Inverter
Max. DC Power12000W
Input Voltage Range160-1000V
Maximum Output Power8800W
Max. AC Apparent Power8800VA
AC Voltage Range310-480V
CommunicationRS485