Loading...
SOFAR 25~50KTLX-G3 User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd.
- 32 -
Figure 4-12 DC cable connection(3)
Step 4: Measure PV voltage of DC input with multimeter, verify DC input cable
polar and connect DC connector with inverter until hearing a slight sound indicated
connection succeed.
Figure 4-13 DC cable connection(4)
Figure 4-14 Use a multimeter to check the positive and negative electrodes
Note Please use multimeter to make sure the PV array positive pole and
negative pole!
Dealing
If need to remove the PV connector from inverter side, please use the
Removal Tool as below diagram, move the connector gently.
Before, moving the positive and negative connector, please make sure
“DC Switch” is on OFF position.