EasyManua.ls Logo

Sofar HYD3000-ES - Page 23

Sofar HYD3000-ES
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23 / 47
MENU
Compatible Batteries
1.PYLON
PYLONTECH US2000 PLUS / US2000B
Note: Please confirm with representative of PYLONTECH that your battery is
compatible with HYD3000/4000/5000/6000-ES
2. DARFON
DARFON 14S31P ESS
3.DEFAULT
LEAD ACID / LEAD CRYSTAL / AQUION battery
4. General Lithium
All batteries that comply with SOFAR’S BMS CAN communication protocol.
5. Alpha. ESS
M48112-P / SMILE-BAT
6. SOLTARO
SL-3KWH / SL-1KWH
4)*Set battery capacity (only for DEFAULT battery type)
Press “Up or “Down” to change the 1
st
digit, press OKto switch to next digit. After changing the battery capacity
per your battery specification, press “Ok, then “Set max charge voltage” will pop up.
5)*Set max charge voltage (only for DEFAULT battery type)
Press Upor “Down” to change the 1
st
digit, press OKto switch to next digit. After changing max charge voltage
per your battery specification, press “Ok, then “Set max charge current” will pop up.
6)*Set max charge current (only for DEFAULT battery type)
Press Upor “Down” to change the 1
st
digit, press OKto switch to next digit. After changing the max charge current
per your battery specification, press “Ok, then “Set max protect voltage” will pop up.
7)*Set max protect voltage (only for DEFAULT battery type)
Press Upor “Downto change the 1
st
digit, press OKto switch to next digit. After changing the max protect voltage
per your battery specification, press “Ok, then “Set min discharge voltage” will pop up.
8)*Set min discharge voltage (only for DEFAULT battery type)
Press Upor Down” to change the 1
st
digit, press OKto switch to next digit. After changing the min discharge
voltage per your battery specification, press “Ok, then “Set max discharge current” will pop up.
9)*Set max discharge current (only for DEFAULT battery type)
Press Upor “Down” to change the 1
st
digit, press OKto switch to next digit. After changing the max discharge
current per your battery specification, press “Ok, then “Set min protect voltage” will pop up.
10)*Set min protect voltage (only for DEFAULT battery type)
Press Upor “Down” to change the 1
st
digit, press OKto switch to next digit. After changing the min protect voltage
per your battery specification, press “Ok, then “Set discharge depth” will pop up.

Related product manuals