EasyManua.ls Logo

Sofar HYD3000-ES - Page 32

Sofar HYD3000-ES
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32 / 47
81>.S1 49.9Hz 103ms
↓
Press “Down”
81>.S2 threshold 51.5Hz 100ms
↓
Press “Down”
81>.S2 49.9Hz 107ms
↓
Press “Down”
81<.S1 threshold 49.5Hz 100ms
↓
Press “Down”
81<.S1 50.0Hz 105ms
↓
Press “Down”
81<.S2 threshold 47.5Hz 100ms
↓
Press “Down”
81<.S2 50.1Hz 107ms
2) Autotest STD
Select “2. Autotest STD”, then press “OK” to start Auto test STD.
The test procedure is same as Autotest Fast, but it’s much more time consuming.
3) PF Time Setting
Select “3. PF Time Setting”, then press “OK”. The following will be shown on the display:
Set: *. *** s
Press “Up” or “Down” to change the 1
st
digit, press “OK” to switch to next digit. After changing all digits, press “OK”.
4) QV Time Setting
Select “4. QV Time Setting”, then press “OK”. The following will be shown on the display:
Set:** s
Press “Up” or “Down” to change the 1
st
digit, press “OK” to switch to next digit. After changing all digits, press “OK”.
5) Control 81.S1
Select “5. Control 81.S1”, press “OK”. Press “up” or “down” to select “Enable 81.S1” or “Disable 81.S1”, press “OK”.