MIVI Technical Manual
REF: 379/4 23
Appendix B: SPECIFIC CONDITIONS OF USE FOR IECEX
MIVI-ADF
Ambient temperature for gas atmosphere:
Ambient temperature depending of the different parts of this apparatus
Temperature class Main body and sensor part
Entry of enclosure (without
pipe)
Entry of enclosure (with pipe)
T4 -20°C ≤ Tamb ≤ +125°C -20°C ≤ Tamb ≤ +100°C -20°C ≤ Tamb ≤ +100°C
T5 -20°C ≤ Tamb ≤ +90°C -20°C ≤ Tamb ≤ +90°C -20°C ≤ Tamb ≤ +90°C
T6 -20°C ≤ Tamb ≤ +75°C -20°C ≤ Tamb ≤ +75°C -20°C ≤ Tamb ≤ +75°C
Ambient temperature for gas and dust atmosphere:
Temperature class
Ambient temperature depending of the different parts of this apparatus
Gas Dust Main body and sensor part
Entry of enclosure
(without pipe)
Entry of enclosure
(with pipe)
T4 T125°C -17°C ≤ Tamb ≤ +125°C -17°C ≤ Tamb ≤ +100°C -17°C ≤ Tamb ≤ +100°C
T5 T90°C -17°C ≤ Tamb ≤ +90°C -17°C ≤ Tamb ≤ +90°C -17°C ≤ Tamb ≤ +90°C
T6 T75°C
-17°C ≤ Tamb ≤ +75°C -17°C ≤ Tamb ≤ +75°C -17°C ≤ Tamb ≤ +75°C
Other specific conditions:
Used special fasteners with yield stress >= 450 MPa.
The special fasteners can be replaced only by the identical fasteners - contact the manufacturer.