F 2 0 0 0 O P E R A T I O N S & M A I N T E N A N C E
Version 1.5 (121506)
6
66
6
Warning
DISCONNECT the unit from an electrical power source before
performing any maintenance on the unit.
S Y S T E M C A S E C L E A N I N G
E X T E R I O R
The exterior of the machine can be cleaned with mild dishwashing detergent and a
clean cloth, and then rinsed with clean water. DO NOT use any all-purpose
cleaners with harsh detergents or abrasives, as these may damage the decals and the
exterior finish. Care should also be taken to avoid spraying or otherwise directing
detergent or water into or around electrical components.
I N T E R I O R
The interior walls of the UV lamp chamber can be cleaned in the same manner as
the exterior.
U V L A M P C L E A N I N G
During UV lamp replacement (see UV Lamp Replacement) cleaning of the new
UV lamps is recommended to maintain peak lamp processing efficiency.
Fingerprints, smudges, dirt and dust particles, etc. will interfere with the UV
radiation process and must therefore be avoided.
To clean the UV lamps, use a 50/50 mixture of rubbing alcohol and clean water on
a lint-free cloth (chamois recommended) and wipe the glass gently. Do not use any
type of commercial glass cleaner. Using another lint-free cloth (chamois
recommended) gently wipe the lamp until completely dry. Allow the lamp to dry
completely (20 minutes) before operating the system.