F 2 0 0 0 O P E R A T I O N S & M A I N T E N A N C E
Version 1.5 (121506)
7
77
7
U V L A M P S
The expected life of the UV lamps may vary, depending on a number of factors
including ambient operating conditions, but will generally average 9,000 hours of
operation. The lamp does not burnout like a regular incandescent bulb, but slowly
becomes less effective. After the expected life, the lamp will no longer
decontaminate the air passing through it effectively, and the lamp should be
replaced.
Warning
DISCONNECT the unit from the electrical power source before
performing any maintenance on the unit. Allow 30 minutes for the
system and lamps to cool down before performing lamp replacement.
Note
The UV Lamp is packaged in its own Styrofoam box. The lamp is fragile and extreme
caution should be taken when handling. Use paper toweling or a clean cloth when handling
the lamp, so as not to get fingerprints on it. Fingerprints will inhibit the production of
ultraviolet light. If you do get fingerprints on the UV lamp, you can clean them off with a
soft, clean cloth lightly dampened with rubbing alcohol. Allow the lamp to dry before
installing and turning on the system.
U V L A M P I N S T A L L A T I O N
Step 1
a) Locate the rear (louvered) panel. Unscrew the
two (2) thumbscrews at the top and bottom of
the panel.
b) Remove the rear panel.
Step 2
a) Locate the front panel and unscrew the two
(2) thumbscrews at the top and bottom of the
panel.
b) Remove the front panel.
Parts Replacement Procedures