9
Code
Category
Pmax
Voc
Isc
Vpmax
Ipmax
140W-01
Single
Crystallin
e Silicon
Module
140W
22.4V
8.33A
17.6V
7.95A
14W-0W-02
Thin-film
Module
140W
29.0V
7.12A
23.0V
6.52A
190W-01
Single
Crystallin
e Silicon
Module
190W
45.2V
5.65A
36.6V
5.2A
130W-01
Thin-film
Module
130W
60.4V
3.41A
46.1V
2.82A
The above parameters are for condition of 25°C, AM1.5 spectrum, and
1000W/m
2
illumination intensity.
Table 3-2: Solar Panels Model and Parameters
Code
For 12V System
For 24V System
For 48V System
140W-01
N in parallel
two in series,
N in parallel
four in series,
N in parallel
140W-02
N in parallel
two in series,
N in parallel
four in series,
N in parallel
190W-01
N in parallel
N in parallel
two in series,
N in parallel
130W-01
N in parallel
N in parallel
two in series,
N in parallel
N means the quantity number required by the output current.
Table 3-3: Solar Panels Model and System Configuration Solution
3.3 Wire Sizing
The maximum input and output current of MPPT-10 is 10A. To ensure the
cable temperature does not exceed the safety range, the copper cable’s area
must be at least 2.5mm
2
. In reality application, user can choose the
appropriate cables according to the system voltage, permitted cable
www.biall.com.pl