EasyManuals Logo

SolarEdge SE10k User Manual

SolarEdge SE10k
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
Chapter 2: Installing the Power Optimizers
Safety
The following notes and warnings apply when installing the power optimizers. Some of
the following may not be applicable to smart modules:
WARNING!
When modifying an existing installation, turn OFF the inverter ON/OFF switch,
the Connection Unit and the AC circuit breaker on the main AC distribution
panel.
CAUTION!
Power optimizers are IP68/NEMA6P rated. Choose a mounting location where
optimizers will not be submerged in water.
CAUTION!
This unit must be operated according to the operating specifications provided
with the unit.
CAUTION!
Cutting the power optimizer input or output cable connector is prohibited and
will void the warranty.
CAUTION!
All PV modules must be connected to a power optimizer.
CAUTION!
If you intend to mount the optimizers directly to the module or module frame,
first consult the module manufacturer for guidance regarding the mounting
location and the impact, if any, on module warranty. Drilling holes in the
module frame should be done according to the module manufacturer
instructions.
-Three Phase System Installation Guide MAN-01-00057-4.1
16 Chapter 2: Installing the Power Optimizers

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge SE10k and is the answer not in the manual?

SolarEdge SE10k Specifications

General IconGeneral
AC Output Power10000 W
Maximum Efficiency98.3%
CoolingNatural Convection
Protection RatingIP65
Rated AC Power10000 W
Max. DC Power13500 W
CEC Weighted Efficiency97.5%
TopologyTransformerless
Number of MPP Trackers2
Warranty12 years
Operating Temperature Range-25°C to 60°C
Communication InterfacesRS485, Ethernet
DC Overvoltage ProtectionType 2

Related product manuals