Main Inverter Status
Status
Inverter
SN 07318000C
Power
50 kW
Voltage
230Vac
Frequency
50 Hz
P_OK: 15 of 20
Optimizers
Connected
Server Comm.
S_OK
(LAN)
Status
Production
Switch
OFF
CosPhi
1.00
Limit
No Limit
Country
USA2
Voltage
350 Vdc
Temp
156 F
Fan
N/A
Switch Off. Production disabled
Commissioning
Inverter: The inverter serial number
Power: The AC output power
Voltage (Vac): The AC output voltage
Frequency: The AC output frequency
S_OK:The connection to the monitoring platform. (Server Connected appears
only if the inverter is connected to the monitoring platform).
Status: The inverter operation status:Off, Not Paired, Night Mode, Error,
Pairing, or Production
Switch: Indicates the position of the inverter ON/OFF/P switch: On, Off, or P
position.
CosPhi: Indicates the ratio between active and reactive power.A negative value
-Three
Phase
System
Installation
Guide
MAN-01-00527-1.2
58 Viewing System Status

Table of Contents