J) Export control
With this function the inverter can control the energy exported to the grid.There
are user value and factory value.The factory value is default which can not be
changed by user.The user value setting by installer must be less than the factory
value. Press up and down button to select and press OK to conrm.
Operation Method
46
I) Work mode
The default work mode of the inverter is Self Use mode. User can set the work mode
as Self Use or Force Time Use here as describe in 3.1.
For the Force Time Use. User can set 2 periods of the start and end time of charger
or discharge. Also can select if charging from grid for each charging period.
>Mode Select
Force time use
Work Mode
> Charge
Start time 1
08:00
Work Mode
>Charger period 1
Charge From Grid
Disable
Work Mode
Charger start time1
Charger end time1
The start time of the rst charger period.
Charger start time2
Charger end time2
Discharger start time1
Discharger end time1
Discharger start time2
Discharger end time2
The end time of the rst charger period.
The start time of the second charger period.
The end time of the second charger period.
The start time of the rst discharger period.
The end time of the rst discharger period.
The start time of the second discharger period.
The end time of the second discharger period.
Parameter
Comment