5. Installation5. Installation
d) Separate the AC plug into three parts as below.
- Hold the middle part of the female insert, rotate the back shell to loose it, and
datach it from female inset.
- Remove the cable nut (with rubber insert) from the back shell.
e) Slide the cable nut and then back shell onto the cable.
f ) Insert the tripped end of each three wires into the appropriate hole in the
female insert, and then tight each screw (to tight each wire in place).
g) Screw down the threaded sleeve the pressure screw.
h) Screw down the pressure screw.
I) Connect the AC plug to the inverter.
Screw the ground screw with allen wrench shown as follow.
AC
WiFi Connection (optional)
Ground Connection
You can read the real time data on the internet either from PC or smartphone
with WiFi monitoring.
a) Open the WiFi lid on the back of the inverter.
b) Plug the Pocket WiFi (from Solax) into the port named “WiFi” on inverter, and
tighten the four screws as below.
c) Connect the WiFi with the router. ( Please refer to “WiFi Setting Guide”.)
d) Set the station account on the Solax web. (Please refer to “WiFi Setting Guide”.)
Connection Step:
5.5.2 Communication Interface
This product has a series communication interfaces : RS 485, USB, DRM.
Operating information like output voltage, current, frequency, fault information, etc.,
can be delivered to PC or other monitoring equipment via these interfaces.
When user wants the information of the power station and manage the entire power
system. We offer RS 485 communication.
RS 485 Communication
1918