1.3.2 Explanation of Symbols
09
08
Type A pprove d
Saf ety
Regu lar Pro ducti on
Sur veill ance
www. tuv.com
ID 111 12274 31
Safety
CE mark.
The inverter complies with the requirementsof the
applicable CE guidelines.
This section gives an explanation of all the symbols shown on the inverter
and on the type label
SolaX X1-Hybrid G4 Series inverter should pair with high voltage battery,
for the specic parameters such as battery type, nominal voltage and
nominal capacity etc., please refer to section 3.3.
Please refer to the matching battery specication for details.
Ø
The inverter can not be disposed together with the
household waste.Disposal information can be found in the
enclosed documentation.
• A faulty ground connection can result in equipment failure, personal
and death injuries, and electromagnetic interference.
• Ensure correct according to grounding to IEC62109 and conductor
diameter according to STANDARD specification.
• Do not connect the grounding end of the equipment in series to
prevent multi-point grounding.
• Electrical appliances must be installed in accordance with the wiring
rules of each country.
For United Kingdom
• The installation that connects the equipment to the supply terminals
shall comply with the requirements of BS 7671.
• Electrical installation of PV system shall comply with requirements of
BS 7671 and IEC 60364-7-712.
• All protective devices cannot be changed.
• User shall ensure that equipment is so installed, designed and
operated to maintain at all times compliance with the requirements of
ESQCR22(1)(a).
Warning!
Battery status