EasyManua.ls Logo

SolaX Power X1-Hybrid-G4 - Technical Data; DC Input; AC Output;Input

SolaX Power X1-Hybrid-G4
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
76
Technical Data / Technische Daten / Fiche technique / Datos técnicos / Dados
Técnicos / Technische gegevens / Dati tecnici / Dane techniczne / Technické údaje /
Tekniska data / Date tehnice /

/ Tekniske data /

/ Tehnilised andmed / Tekniset tiedot / Tehnički podaci / Műszaki adatok / Techniniai
duomenys / Tehniskie dati / Technické údaje / Tehnični podatki / Teknik Bilgiler /
Dados Técnicos /

DC input (apply to version D/M)
Model X1-Hybrid-3.0 X1-Hybrid-3.7
X1-Hybrid-5.0
X1-Hybrid-
5.0K-D
X1-Hybrid-6.0 X1-Hybrid-7.5
Max. recommended PV power¹ [W] 6000 7400 10000 12000 15000
Max PV voltage [d.c. V] 600 600 600 600 600
Nominal DC operating voltage [d.c. V] 360 360 360 360 360
MPPT voltage range [d.c. V] 70-550
MPPT full power voltage range [d.c. V] 115-480 135-480 190-480 225-480 280-480
Max. PV curent [d.c. A] 16/16 16/16 16/16 16/16 16/16
Isc PV array short circuit [d.c. A] 20/20 20/20 20/20 20/20 20/20
Start output voltage [d.c. V] 90 90 90 90 90
Max. inverter backfeed current to the
array [d.c. V]
0 0 0 0 0
No. of MPP trackers 2 2 2 2 2
Strings per MPP trackers 1 1 1 1 1
*
Marked with "¹" indicates that a single channel MPPT can only input a maximum of 5000W.
AC output/ input (apply to version D/M)
Model X1-Hybrid-3.0 X1-Hybrid-3.7
X1-Hybrid-5.0
X1-Hybrid-
5.0K-D
X1-Hybrid-6.0 X1-Hybrid-7.5
AC output
Rated output apparent power [VA] 3000 3680
5000
(Germany
4600, AU 4999)
(5.0K-D 4999)
6000
7500
(PEA 6900)
Max
.
output apparent power [VA] 3300 3680
5500
(Germany
4600, AU 4999)
(5.0K-D 4999)
6600
7500
(PEA 7300)
Nominal AC voltage [a.c. V] 220/230/240 (180 to 270)
Frequency [Hz] 50/60
Rated output current [a.c. A] 13 16 21.7 26.1 32.6
Max. output continuous current
[a.c. A]
14.4 16
23.9
(Germany 20,
AU 21.7)
28.6
32.6
(PEA 33)
Current (inrush) (at 50µs) [a.c. A] 10
Maximum output fault current
(at 1ms) [a.c. A]
91
Maximum output overcurrent
protection [a.c. A]
65
Power factor range 0.8 leading - 0.8 lagging
Total harmonic distortion (THDi) < 2 %
AC input
Max. apparent power [VA] 6300 7360 9200 9200 9200
Rated AC power [W] 3000 3680 5000 6000 7500
Nominal AC voltage [a.c. V] 220/230/240 (180 to 270
Frequency [Hz] 50/60
Max
.
AC input current [a.c. A] 27.4 32 40 40 40
Power factor range 0.8 leading - 0.8 lagging