77
• Battery (apply to version D/M)
Model X1-Hybrid-3.0 X1-Hybrid-3.7
X1-Hybrid-5.0
X1-Hybrid-
5.0K-D
X1-Hybrid-6.0 X1-Hybrid-7.5
Battery type Lithium batteries
Battery voltage range [d.c. V] 80-480
Max. continuous charge/ discharge
current [d.c. A]
30
Communication interface CAN/RS485
Reverse connection protection Yes
• Efficiency, Safety and Protection (apply to version D/M)
Model X1-Hybrid-3.0 X1-Hybrid-3.7
X1-Hybrid-5.0
X1-Hybrid-
5.0K-D
X1-Hybrid-6.0 X1-Hybrid-7.5
Efficiency
MPPT efficiency 99.9% 99.9% 99.9% 99.9% 99.9%
European efficiency 97.0% 97.0% 97.0% 97.0% 97.0%
Maximum efficiency 97.6% 97.6% 97.6% 97.6% 97.6%
Max. battery charge efficiency (PV to
BAT) (@ full load)
97.0% 97.0% 97.0% 97.0% 97.0%
Max. battery discharge efficiency (BAT
to AC) (@ full load)
97.0% 97.0% 97.0% 97.0% 97.0%
Safety and Protection
Safety IEC/EN 62109-1/-2
Grid monitoring EN50549, VDE-AR-N 4105, C10/11, CEI 0-21, G98, G99, AS/NZS 4777.2
DC SPD protection Integrated
AC SPD protection Integrated
Over
/
under voltage protection Yes
Grid protection Yes
DC injection monitoring Yes
Back feed current monitoring Yes
Residual current detection Yes
Active anti-islanding method Frequency Shift
Over load protection Yes
Over heat protection Yes
Array insulation resistance detection Yes
• EPS (Off-grid) output (apply to version D/M)
Model X1-Hybrid-3.0 X1-Hybrid-3.7
X1-Hybrid-5.0
X1-Hybrid-
5.0K-D
X1-Hybrid-6.0 X1-Hybrid-7.5
Rated EPS apparent power [VA] 3000 3680 5000 6000 7500
Nominal EPS voltage [a.c. V] 230 VAC
Frequency 50/60
Rated EPS current [a.c. A] 13 16 21.7 26.1 32.6
EPS (Off-grid) peak power [VA] 6000, 10s 6000, 10s 7500, 10s 9000, 10s 11250, 10s
Switching time (typical value) [ms] internal switch < 10, external switch < 100
Total harmonic distortion (THDv) < 2 %