What should I do if my SolaX Power X1-Hybrid-5.0-LV Inverter displays 'Low soc of grid-connected battery'?
- AApril TravisSep 4, 2025
If your SolaX Power Inverter displays 'Low soc of grid-connected battery', stop discharging and start charging.
What should I do if my SolaX Power X1-Hybrid-5.0-LV Inverter displays 'Low soc of grid-connected battery'?
If your SolaX Power Inverter displays 'Low soc of grid-connected battery', stop discharging and start charging.
What should I do if my SolaX Power X1-Hybrid-5.0-LV Inverter displays 'Arc fault'?
If your SolaX Power Inverter is showing an 'Arc fault' message, wait for a while and observe if it returns to normal operation.
What to do if my SolaX Power X1-Hybrid-5.0-LV Inverter displays 'PV connection configuration error'?
If your SolaX Power Inverter shows a 'PV connection configuration error', turn off the PV, battery, and power grid. Then, restart the inverter and confirm whether the PV connection is correct.
What should I do if my SolaX Power Inverter displays 'Low soc of off-grid battery'?
If your SolaX Power Inverter displays 'Low soc of off-grid battery', stop discharging and start charging.
What should I do if my SolaX Power X1-Hybrid-5.0-LV Inverter displays 'BST2 hardware overcurrent'?
If your SolaX Power Inverter displays 'BST2 hardware overcurrent', wait for a while to see if it returns to normal.
What should I do if my SolaX Power X1-Hybrid-5.0-LV Inverter displays 'The grid voltage exceeds the allowable value 2'?
If your SolaX Power Inverter displays 'The grid voltage exceeds the allowable value 2', check whether the grid voltage is within the normal working range.
What should I do if my SolaX Power Inverter displays 'The grid voltage is lower than the allowable value 1'?
If your SolaX Power Inverter displays 'The grid voltage is lower than the allowable value 1', check whether the grid voltage is within the normal working range.
What should I do if my SolaX Power X1-Hybrid-5.0-LV displays 'BST overpower'?
If your SolaX Power Inverter displays 'BST overpower', wait for a while to see if it returns to normal.
What to do if my SolaX Power Inverter displays 'Battery type configuration error'?
If your SolaX Power Inverter displays 'Battery type configuration error', turn off the PV, battery, and power grid, restart the inverter, and confirm whether the battery type is correct.
What to do if SolaX Power X1-Hybrid-5.0-LV Inverter shows '1.1 times overload'?
If your SolaX Power Inverter displays '1.1 times overload', turn off any high-power load connected to the inverter.
Max Efficiency | 97.6% |
---|---|
Battery Voltage | 48 V |
Start Voltage | 120V |
MPPT Voltage Range | 120 V - 550 V |
Number of MPPTs | 2 |
Nominal Output Voltage | 230 V |
Rated AC Voltage | 230 V |
AC Voltage Range | 180-280V |
MPPT Range | 120 V - 550 V |
Max. DC Input Current per MPPT | 11 A |
Protection Degree | IP65 |
Rated Power | 5000W |
Battery Compatibility | Lithium-ion battery |
Max. Discharging Power | 5000W |
Max. DC Input Power | 6500W |
Max. Output Power | 5000VA |
AC Output Power | 5000W |
Max. AC Output Power | 5000VA |
AC Frequency | 50/60 Hz |
Max. DC Input Power (Alternative) | 6500W |
Operating Temperature Range | -25°C to 60°C |
Cooling Method | Natural Convection |
Communication | RS485, Ethernet, WiFi |
Max. Charging Power | 5000W |
Covers critical safety warnings regarding high voltages, hot surfaces, radiation, grounding, and electric shock.
Details the necessity and types of surge protection for PV systems.
Explains the role of RCM, trip thresholds, and RCD Type B recommendations.
Provides guidelines for pairing the inverter with high voltage batteries.
Details essential precautions for safe and effective inverter installation.
Step-by-step instructions for physically mounting the inverter onto its bracket.
Details how to connect photovoltaic panels to the inverter's inputs.
Explains connections to the grid, generator, and EPS output.
Specifies power and operational requirements for loads connected to the EPS output.
Provides step-by-step instructions for wiring Grid, GEN, and EPS cables.
Guides on connecting the battery system to the inverter.
Outlines prerequisites and safety measures for battery connection.
Step-by-step procedure for connecting battery cables.
Covers various communication port definitions and connections.
Identifies and describes the function of each communication port.
Explains how to connect current sensors (CT) and electric meters.
Details connections for BMS, DRM, and COM ports.
Specifies pinouts and connection for the Battery Management System (BMS) port.
Explains the COM port's use for monitoring and external equipment control.
Describes how to connect multiple inverters in parallel.
Shows the setup for connecting up to 10 inverters in parallel.
Explains the critical steps for performing a proper ground connection.
Detailed procedure for connecting the ground wire for safety.
Describes how to connect monitoring accessories like WiFi, LAN, and 4G dongles.
A checklist of pre-operation checks before starting the inverter.
Instructions on how to safely start and operate the inverter.
Detailed steps for powering on and initiating the inverter's operation.
Lists specific faults, their diagnoses, and suggested solutions for various error types.