Installation
32
Reserve enough space when installing inverter (at least 30 cm) for heat dis-
sipation. The heat dissipation space from inverter to the ground is 50 cm. It is
recommended to install the inverter more than 100 cm above the ground.
For multi-inverter installation scenarios, the inline installation method is rec-
ommended; it is not recommended to install multiple inverters in stacks. If you
choose stack installation, please refer to the installation separation distance
below.
30 cm 30 cm
90 cm
100 cm
5.5.3 Installation Space Requirements
50 cm
30 cm 30 cm
30 cm
50 cm30 cm
100 cm
100 cm90 cm
90 cm
100 cm
100 cm
30 cm