THERMOCUBE 200/300/400 THERMOELECTRIC CHILLER MANUAL 52-11300-1
SOLID STATE COOLING SYSTEMS, 167 MYERS CORNERS ROAD, WAPPINGERS FALLS, NY 12590 1
TELEPHONE: (845) 296-1300 FAX: (845) 296-1303 WEB: WWW.SSCOOLING.COM VERSION M28
T
ABLE OF CONTENTS
SAFETY PRECAUTIONS AND SYMBOLS _____________________________________________ 3
SECTION 1 _________________________________________________________________________ 4
INTRODUCTION ______________________________________________________________________ 4
SECTION 2 _________________________________________________________________________ 5
SPECIFICATIONS _____________________________________________________________________ 5
SECTION 3 _________________________________________________________________________ 7
HOOK UP __________________________________________________________________________ 7
3.1 Electrical Connections (see figure 3) _______________________________________________ 8
3.2 Plumbing Connections (see figure 3) _______________________________________________ 8
3.3 Air Considerations ____________________________________________________________ 10
3.4 Coolant Fill __________________________________________________________________ 10
SECTION 4 ________________________________________________________________________ 11
START UP _________________________________________________________________________ 11
SECTION 5 ________________________________________________________________________ 11
OPERATION _______________________________________________________________________ 11
5.1 Simple Operation _____________________________________________________________ 12
5.2 Advanced Operation ___________________________________________________________ 12
5.3 Alarms ______________________________________________________________________ 15
5.4 Auto-tuning __________________________________________________________________ 15
5.5 Manual Tuning _______________________________________________________________ 16
5.6 Drain Procedure ______________________________________________________________ 17
SECTION 6 ________________________________________________________________________ 17
SYSTEM ALARMS/TROUBLESHOOTING ___________________________________________________ 17
SECTION 7 ________________________________________________________________________ 19
THERMOCUBE OPTIONS ______________________________________________________________ 19
7.1 ThermoCube Options and Part Number ____________________________________________ 19
7.2 RS-232 Communications Option__________________________________________________ 20
7.3 Other Options ________________________________________________________________ 23
SECTION 8 ________________________________________________________________________ 26
CLEANING YOUR CHILLER ____________________________________________________________ 26
SECTION 9 ________________________________________________________________________ 26
TECHNICAL SUPPORT ________________________________________________________________ 26
SECTION 10 _______________________________________________________________________ 27
MSDS FOR COOLANTS _______________________________________________________________ 27
10.1 MSDS for Koolance LIQ-702 Coolant Fluid _______________________________________ 27
10.2 MSDS for Ethylene Glycol _____________________________________________________ 32
WARRANTY POLICY ______________________________________________________________ 39