  • B
    Brenda Mccarthy MDAug 31, 2025
    What should I do if my SOLIS Inverter shows UN-Vbatt?
    • K
      kryanAug 31, 2025
      If your SOLIS Inverter displays UN-Vbatt, restart the system to see if the fault clears. If the issue persists, it's recommended to contact the manufacturer's customer service for further assistance.
  • M
    Manuel HuffmanAug 25, 2025
    Why does my SOLIS S6-EH3P29.9K-H show NO-Battery, and how do I fix it?
    • M
      Miguel LopezAug 25, 2025
      If your SOLIS Inverter shows NO-Battery, check the information page to verify that the battery voltage is within the specified standards. Also, measure the battery voltage at the plug.
  • J
    Jennifer BlairSep 23, 2025
    What does Grid disturbance 02 mean on SOLIS S6-EH3P29.9K-H?
    • J
      James MccarthySep 23, 2025
      A 'Grid disturbance 02' error on your SOLIS Inverter suggests a problem with the power grid or AC cable connection. Check if the grid is seriously distorted and ensure the AC cable is reliably connected.
  • J
    John HollandSep 5, 2025
    How to troubleshoot OV-TEM error on SOLIS S6-EH3P29.9K-H Inverter?
    • S
      Susan RiversSep 5, 2025
      If your SOLIS Inverter is showing an OV-TEM error, start by checking if the installation location meets the requirements specified in the user manual. Then, try to lower the ambient temperature around the inverter. After doing so, restart the inverter after fifteen minutes. If the error continues, contact the factory's customer service.
  • Y
    ysmithSep 10, 2025
    What does 'OV-Vbatt' mean on my SOLIS S6-EH3P29.9K-H and how to solve it?
    • S
      Sydney MortonSep 10, 2025
      The 'OV-Vbatt' error on your SOLIS Inverter indicates an over-voltage issue with the battery. Verify the battery voltage is within the specified standards. Also, measure the battery voltage at the inverter connection point. If problems persist, contact your battery manufacturer for service.
  • D
    David ArmstrongSep 3, 2025
    What does UN-TEM (103A DATA:0000) error mean on my SOLIS Inverter?
    • T
      Terrance HudsonSep 3, 2025
      If your SOLIS Inverter displays UN-TEM (103A DATA:0000), check the working environment temperature of the inverter. Restart the system to confirm if the fault continues.
  • G
    guykennedyAug 29, 2025
    What does LmtByEPM mean on my SOLIS S6-EH3P29.9K-H?
    • M
      Matthew SawyerAug 29, 2025
      If your SOLIS Inverter is showing 'LmtByEPM', confirm the inverter is connected to an external EPM/meter to prevent reverse current. Also, check if the inverter is controlled by an external third-party device and verify if the power setting of the inverter power control is limited. You may also need to verify settings in section 6.6.7 and check your meter readings.
  • P
    pcookSep 12, 2025
    What does 'BatName-FAIL' mean on my SOLIS S6-EH3P29.9K-H Inverter and how to resolve it?
    • C
      cookcaitlynSep 12, 2025
      If your SOLIS Inverter displays 'BatName-FAIL', confirm whether the battery model selection is consistent with the actual one.
  • L
    Laura JohnsonSep 7, 2025
    How to fix ILeak-Check error on SOLIS Inverter?
    • R
      Raven FullerSep 7, 2025
      If your SOLIS Inverter shows an ILeak-Check error, upgrade the software to the latest version. If the fault continues after the upgrade, contact the factory's customer service.
  • J
    Joshua CarrAug 27, 2025
    What to do if SOLIS S6-EH3P29.9K-H Inverter displays OV-ILLC (1052 DATA:0000)?
    • A
      Amanda RobinsonAug 27, 2025
      If your SOLIS Inverter displays OV-ILLC (1052 DATA:0000), it may be due to an overloaded backup load. Check whether the backup load is overloaded. If the problem continues, restart the system to see if the fault clears.