EasyManua.ls Logo

SOLIS S6-EH3P5K2-H - User Manual

SOLIS S6-EH3P5K2-H
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
User Manual
for S6 Series Hybrid Inverter
Version 1.2, Release Date: 04,2023
Applicable models
S6-EH3P5K2-H
S6-EH3P6K2-H
S6-EH3P8K2-H
S6-EH3P10K2-H
S6-EH3P3K-H-EU
S6-EH3P4K-H-EU
S6-EH3P5K-H-EU
S6-EH3P6K-H-EU
S6-EH3P8K-H-EU
S6-EH3P10K-H-EU
S6-EH3P10K-H-EU-BE
Applicable System
Three phase system

Questions and Answers

  • K
    Krista JamesAug 31, 2025
    What should I do if my SOLIS Inverter shows UN-Vbatt?
    • H
      hillamyAug 31, 2025
      If your SOLIS Inverter displays UN-Vbatt, restart the system to see if the fault clears. If the issue persists, it's recommended to contact the manufacturer's customer service for further assistance.
  • K
    Kristen MuellerAug 25, 2025
    Why does my SOLIS S6-EH3P5K2-H Inverter show NO-Battery, and how do I fix it?
    • S
      Seth CooperAug 25, 2025
      If your SOLIS Inverter shows NO-Battery, check the information page to verify that the battery voltage is within the specified standards. Also, measure the battery voltage at the plug.
  • H
    Heather WilliamsSep 23, 2025
    What does Grid disturbance 02 mean on SOLIS Inverter?
    • R
      Richard HesterSep 23, 2025
      A 'Grid disturbance 02' error on your SOLIS Inverter suggests a problem with the power grid or AC cable connection. Check if the grid is seriously distorted and ensure the AC cable is reliably connected.
  • A
    alyssa30Sep 5, 2025
    How to troubleshoot OV-TEM error on SOLIS S6-EH3P5K2-H?
    • L
      Lindsay GibsonSep 5, 2025
      If your SOLIS Inverter is showing an OV-TEM error, start by checking if the installation location meets the requirements specified in the user manual. Then, try to lower the ambient temperature around the inverter. After doing so, restart the inverter after fifteen minutes. If the error continues, contact the factory's customer service.
  • B
    brittanyjohnsonSep 10, 2025
    What does 'OV-Vbatt' mean on my SOLIS S6-EH3P5K2-H Inverter and how to solve it?
    • T
      Timothy HernandezSep 10, 2025
      The 'OV-Vbatt' error on your SOLIS Inverter indicates an over-voltage issue with the battery. Verify the battery voltage is within the specified standards. Also, measure the battery voltage at the inverter connection point. If problems persist, contact your battery manufacturer for service.
  • C
    Cindy VanceSep 3, 2025
    What does UN-TEM (103A DATA:0000) error mean on my SOLIS S6-EH3P5K2-H Inverter?
    • T
      Thomas NicholsonSep 3, 2025
      If your SOLIS Inverter displays UN-TEM (103A DATA:0000), check the working environment temperature of the inverter. Restart the system to confirm if the fault continues.
  • M
    Mrs. Lisa DiazAug 29, 2025
    What does LmtByEPM mean on my SOLIS Inverter?
    • A
      Andrew GrantAug 29, 2025
      If your SOLIS Inverter is showing 'LmtByEPM', confirm the inverter is connected to an external EPM/meter to prevent reverse current. Also, check if the inverter is controlled by an external third-party device and verify if the power setting of the inverter power control is limited. You may also need to verify settings in section 6.6.7 and check your meter readings.
  • C
    Christopher VillarrealSep 12, 2025
    What does 'BatName-FAIL' mean on my SOLIS S6-EH3P5K2-H Inverter and how to resolve it?
    • B
      Brandon HayesSep 12, 2025
      If your SOLIS Inverter displays 'BatName-FAIL', confirm whether the battery model selection is consistent with the actual one.
  • S
    Stephanie RiddleSep 7, 2025
    How to fix ILeak-Check error on SOLIS S6-EH3P5K2-H?
    • L
      Leslie MacdonaldSep 7, 2025
      If your SOLIS Inverter shows an ILeak-Check error, upgrade the software to the latest version. If the fault continues after the upgrade, contact the factory's customer service.
  • D
    Desiree SingletonAug 27, 2025
    What to do if SOLIS S6-EH3P5K2-H Inverter displays OV-ILLC (1052 DATA:0000)?
    • J
      Jeffrey RaymondAug 27, 2025
      If your SOLIS Inverter displays OV-ILLC (1052 DATA:0000), it may be due to an overloaded backup load. Check whether the backup load is overloaded. If the problem continues, restart the system to see if the fault clears.

SOLIS S6-EH3P5K2-H Specifications

General IconGeneral
ModelS6-EH3P5K2-H
TypeHybrid Inverter
Rated Power5 kW
Max. Input Voltage600 V
Number of MPPT Trackers2
Rated AC Output Power5 kW
Max. AC Apparent Power5.5 kVA
Rated Grid Frequency50/60 Hz
Total Harmonic Distortion (THD)<3%
Power Factor0.8 leading to 0.8 lagging
DC SwitchIntegrated
Protection Degree (IP)IP65
Operating Temperature Range-25°C to +60°C
TopologyTransformerless
Weight25 kg
Cooling MethodNatural Convection
Protection ClassClass I
Efficiency98.2%
Max. DC Input Power6.5 kW
MPPT Voltage Range90-550 V
Rated Grid Voltage230 V / 400 V
Grid Voltage Range180 V - 280 V
CommunicationRS485, WiFi

Related product manuals