EasyManua.ls Logo

SOLIS S6-GR1P6K - User Manual

SOLIS S6-GR1P6K
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
User Manual
for S6 Series Grid Inverter
Version 1.0, Release Date: 04,2023
Applicable models
S6-GR1P2.5K-S
S6-GR1P3K-S
S6-GR1P3.6K-S
S6-GR1P4K-S
S6-GR1P4.6K-S
S6-GR1P5K-S
S6-GR1P6K-S
Applicable System
Single phase system

Other manuals for SOLIS S6-GR1P6K

Questions and Answers

  • J
    Jesus ColeAug 31, 2025
    What should I do if my SOLIS S6-GR1P6K shows UN-Vbatt?
    • D
      dawn99Aug 31, 2025
      If your SOLIS Inverter displays UN-Vbatt, restart the system to see if the fault clears. If the issue persists, it's recommended to contact the manufacturer's customer service for further assistance.
  • D
    Danny RodriguezAug 25, 2025
    Why does my SOLIS S6-GR1P6K show NO-Battery, and how do I fix it?
    • C
      christian22Aug 25, 2025
      If your SOLIS Inverter shows NO-Battery, check the information page to verify that the battery voltage is within the specified standards. Also, measure the battery voltage at the plug.
  • H
    Heather GrahamSep 23, 2025
    What does Grid disturbance 02 mean on SOLIS S6-GR1P6K?
    • C
      Carla McdanielSep 23, 2025
      A 'Grid disturbance 02' error on your SOLIS Inverter suggests a problem with the power grid or AC cable connection. Check if the grid is seriously distorted and ensure the AC cable is reliably connected.
  • L
    Lori HopkinsSep 5, 2025
    How to troubleshoot OV-TEM error on SOLIS Inverter?
    • R
      Raymond ChandlerSep 5, 2025
      If your SOLIS Inverter is showing an OV-TEM error, start by checking if the installation location meets the requirements specified in the user manual. Then, try to lower the ambient temperature around the inverter. After doing so, restart the inverter after fifteen minutes. If the error continues, contact the factory's customer service.
  • D
    Dawn WilsonSep 10, 2025
    What does 'OV-Vbatt' mean on my SOLIS S6-GR1P6K and how to solve it?
    • X
      xsalinasSep 10, 2025
      The 'OV-Vbatt' error on your SOLIS Inverter indicates an over-voltage issue with the battery. Verify the battery voltage is within the specified standards. Also, measure the battery voltage at the inverter connection point. If problems persist, contact your battery manufacturer for service.
  • M
    Maxwell BakerSep 3, 2025
    What does UN-TEM (103A DATA:0000) error mean on my SOLIS S6-GR1P6K Inverter?
    • L
      Logan HaleySep 3, 2025
      If your SOLIS Inverter displays UN-TEM (103A DATA:0000), check the working environment temperature of the inverter. Restart the system to confirm if the fault continues.
  • K
    kyle83Aug 29, 2025
    What does LmtByEPM mean on my SOLIS S6-GR1P6K?
    • M
      Michael RyanAug 29, 2025
      If your SOLIS Inverter is showing 'LmtByEPM', confirm the inverter is connected to an external EPM/meter to prevent reverse current. Also, check if the inverter is controlled by an external third-party device and verify if the power setting of the inverter power control is limited. You may also need to verify settings in section 6.6.7 and check your meter readings.
  • C
    Christian LopezSep 12, 2025
    What does 'BatName-FAIL' mean on my SOLIS Inverter and how to resolve it?
    • M
      Melissa WilsonSep 12, 2025
      If your SOLIS Inverter displays 'BatName-FAIL', confirm whether the battery model selection is consistent with the actual one.
  • K
    Karen GordonSep 7, 2025
    How to fix ILeak-Check error on SOLIS Inverter?
    • T
      Trevor LopezSep 7, 2025
      If your SOLIS Inverter shows an ILeak-Check error, upgrade the software to the latest version. If the fault continues after the upgrade, contact the factory's customer service.
  • N
    Nicole JohnsonAug 27, 2025
    What to do if SOLIS Inverter displays OV-ILLC (1052 DATA:0000)?
    • P
      Paige FisherAug 27, 2025
      If your SOLIS Inverter displays OV-ILLC (1052 DATA:0000), it may be due to an overloaded backup load. Check whether the backup load is overloaded. If the problem continues, restart the system to see if the fault clears.

SOLIS S6-GR1P6K Specifications

General IconGeneral
ModelS6-GR1P6K
Rated Output Power6000 W
Max. Input Voltage600 V
Start-up Voltage90 V
Number of MPPT Trackers2
MPPT Efficiency99.9%
Nominal AC Output Power6000 W
Nominal AC Voltage230 V
AC Voltage Range180-280 V
Nominal Grid Frequency50/60 Hz
THDi<3%
DC Connection TypeMC4
Protection DegreeIP65
TopologyTransformerless
Cooling MethodNatural convection
Max. DC Input Power9000 W
Max. AC Apparent Power6000 VA
Operating Temperature Range-25°C to 60°C
TypeSingle-phase inverter

Related product manuals