Questions and Answers

  • E
    Emily PerkinsAug 27, 2025
    What does ARC- FAULT (1041 DATA:0000) mean on SOLIS Inverter and how to fix it?
    • X
      xmontgomeryAug 27, 2025
      The ARC- FAULT (1041 DATA:0000) error on your SOLIS Inverter indicates a potential arc fault. Start by verifying that all connections within your PV system are tight. If further adjustment is needed, arc fault settings can be changed in advanced settings.
  • W
    Wayne WatkinsAug 27, 2025
    Why is my SOLIS S6-GR1P6K showing OV-DC01 (1020 DATA:0001)?
    • H
      Holly WelchAug 27, 2025
      The OV-DC01 (1020 DATA:0001) error on your SOLIS Inverter indicates a potential issue with the PV voltage. Check if the PV voltage is abnormal. If the issue persists, restart the system to confirm that the fault continues.
  • N
    Nicole JohnsonAug 27, 2025
    What to do if SOLIS Inverter displays OV-ILLC (1052 DATA:0000)?
    • P
      Paige FisherAug 27, 2025
      If your SOLIS Inverter displays OV-ILLC (1052 DATA:0000), it may be due to an overloaded backup load. Check whether the backup load is overloaded. If the problem continues, restart the system to see if the fault clears.
  • R
    Richard BellSep 3, 2025
    How do I troubleshoot PV ISO-PRO01 (1033 DATA:0001) error on my SOLIS Inverter?
    • N
      Nicholas WebbSep 3, 2025
      If your SOLIS Inverter displays PV ISO-PRO01 (1033 DATA:0001), check whether the PV strings have insulation problems and whether the PV cable is damaged.
  • L
    Lori HopkinsSep 5, 2025
    How to troubleshoot OV-TEM error on SOLIS Inverter?
    • R
      Raymond ChandlerSep 5, 2025
      If your SOLIS Inverter is showing an OV-TEM error, start by checking if the installation location meets the requirements specified in the user manual. Then, try to lower the ambient temperature around the inverter. After doing so, restart the inverter after fifteen minutes. If the error continues, contact the factory's customer service.
  • K
    Karen GordonSep 7, 2025
    How to fix ILeak-Check error on SOLIS Inverter?
    • T
      Trevor LopezSep 7, 2025
      If your SOLIS Inverter shows an ILeak-Check error, upgrade the software to the latest version. If the fault continues after the upgrade, contact the factory's customer service.
  • C
    cheryl52Sep 22, 2025
    What to do if my SOLIS S6-GR1P6K displays Fan Alarm?
    • S
      Stephanie AlexanderSep 22, 2025
      If your SOLIS Inverter shows a Fan Alarm, check if the internal fan is working correctly or if it is jammed.
  • T
    tonywigginsSep 17, 2025
    How to troubleshoot battery overcurrent on SOLIS S6-GR1P6K Inverter?
    • J
      Jessica BenitezSep 18, 2025
      If your SOLIS Inverter is showing a battery overcurrent error, restart the inverter.
  • R
    Robert NguyenAug 25, 2025
    Why does my SOLIS S6-GR1P6K Inverter show a NO-Grid error?
    • T
      Tiffany MatthewsAug 26, 2025
      If your SOLIS Inverter displays a NO-Grid error, first verify that the inverter is properly connected to the power grid. Next, check if the connected power grid is functioning normally. If the mains connection is normal, it is recommended to contact maintenance staff.
  • K
    kyle99Aug 25, 2025
    What to do if my SOLIS S6-GR1P6K Inverter displays GRID-INTF02 (1046 DATA:0000)?
    • R
      Ryan HawkinsAug 25, 2025
      If your SOLIS Inverter displays GRID-INTF02 (1046 DATA:0000), confirm whether the grid is seriously distorted and check whether the AC cable is connected reliably.

SOLIS S6-GR1P6K Specifications

General IconGeneral
ModelS6-GR1P6K
Rated Output Power6000 W
Max. Input Voltage600 V
Start-up Voltage90 V
Number of MPPT Trackers2
MPPT Efficiency99.9%
Nominal AC Output Power6000 W
Nominal AC Voltage230 V
AC Voltage Range180-280 V
Nominal Grid Frequency50/60 Hz
THDi<3%
DC Connection TypeMC4
Protection DegreeIP65
TopologyTransformerless
Cooling MethodNatural convection
Max. DC Input Power9000 W
Max. AC Apparent Power6000 VA
Operating Temperature Range-25°C to 60°C
TypeSingle-phase inverter