    Samuel AllisonSep 12, 2025
    What does 'DC-INTF. (1027 DATA:0000)' mean on my SOLIS S6-GR1P6K and how can I solve it?
    • M
      Melissa SavageSep 12, 2025
      If your SOLIS Inverter shows 'DC-INTF. (1027 DATA:0000)', it indicates a DC interface problem. Check if the DC wires are connected correctly without loose connections.
  • K
    Kevin SchroederSep 12, 2025
    What does 'PV ISO-PRO01 (1033 DATA:0001)' mean on my SOLIS Inverter and how to fix it?
    • J
      Jessica CastroSep 12, 2025
      The error 'PV ISO-PRO01 (1033 DATA:0001)' on your SOLIS Inverter suggests a problem with PV string insulation. Check whether the PV strings have insulation problems and whether the PV cable is damaged.
  • A
    Alexandra WhiteSep 12, 2025
    What does '12Power-FAULT (1038 DATA:0000)' mean on a SOLIS Inverter and how to resolve it?
    • D
      Dwayne PorterSep 12, 2025
      The error '12Power-FAULT (1038 DATA:0000)' on your SOLIS Inverter indicates a power fault. Check for current leakage to ground, verify your grounding, and ensure all wires are in good condition and not leaking current to ground.
  • A
    Amanda PriceSep 12, 2025
    What does 'ARC- FAULT (1041 DATA:0000)' mean on my SOLIS S6-GR1P6K Inverter and how can I fix it?
    • T
      terrimcgeeSep 12, 2025
      The error 'ARC- FAULT (1041 DATA:0000)' on your SOLIS Inverter indicates an arc fault. Verify connections are tight within your PV system. If further adjustment is necessary, arc fault settings can be changed in advanced settings.
  • M
    Matthew CarneySep 12, 2025
    What does 'OV-G-I (1018 DATA:0000)' mean on my SOLIS S6-GR1P6K and how do I fix it?
    • C
      Carol FreemanSep 12, 2025
      The error 'OV-G-I (1018 DATA:0000)' on your SOLIS Inverter indicates an issue with grid current. Confirm that the grid is not abnormal and that the AC cable connection is normal. If the problem continues, restart the system.
  • C
    Christian LopezSep 12, 2025
    What does 'BatName-FAIL' mean on my SOLIS Inverter and how to resolve it?
    • M
      Melissa WilsonSep 12, 2025
      If your SOLIS Inverter displays 'BatName-FAIL', confirm whether the battery model selection is consistent with the actual one.
  • C
    codystewartSep 12, 2025
    What does 'OV-Vbackup' mean on my SOLIS S6-GR1P6K Inverter and how to fix it?
    • D
      Destiny PollardSep 12, 2025
      The 'OV-Vbackup' error on your SOLIS Inverter indicates an over-voltage issue with the backup. Check whether the backup port wiring is normal. If the issue persists, restart the system.
  • L
    Lauren RobinsonSep 13, 2025
    What does 'GRID-INTF02 (1046 DATA:0000)' mean on my SOLIS Inverter and how to fix it?
    • T
      Tyler ReynoldsSep 13, 2025
      The error 'GRID-INTF02 (1046 DATA:0000)' on your SOLIS Inverter indicates a grid interface issue. Confirm whether the grid is seriously distorted and check whether the AC cable is connected reliably.
  • L
    Laura CampbellSep 13, 2025
    What does 'OV-ILLC (1052 DATA:0000)' mean on my SOLIS S6-GR1P6K Inverter and how to resolve it?
    • B
      billy19Sep 13, 2025
      If your SOLIS Inverter displays 'OV-ILLC (1052 DATA:0000)', it indicates an overload issue with the backup load. Check whether the backup load is overloaded. If the issue persists, restart the system.
  • U
    uarroyoSep 13, 2025
    What is 'LmtByVg' on my SOLIS S6-GR1P6K and how do I handle it?
    • R
      Richard Ashley DDSSep 13, 2025
      The 'LmtByVg' message on your SOLIS Inverter is triggered by local safety regulations when the grid voltage is high, activating Volt-watt working mode. Generally, this does not require intervention. However, if it's due to a factory test error, you can disable this mode via the LCD: Main menu ? Advanced Settings ? Password 0010 ? STD mode settings ? Working Mode ? Working mode: NULL ? Save and exit.

SOLIS S6-GR1P6K Specifications

General IconGeneral
ModelS6-GR1P6K
Rated Output Power6000 W
Max. Input Voltage600 V
Start-up Voltage90 V
Number of MPPT Trackers2
MPPT Efficiency99.9%
Nominal AC Output Power6000 W
Nominal AC Voltage230 V
AC Voltage Range180-280 V
Nominal Grid Frequency50/60 Hz
THDi<3%
DC Connection TypeMC4
Protection DegreeIP65
TopologyTransformerless
Cooling MethodNatural convection
Max. DC Input Power9000 W
Max. AC Apparent Power6000 VA
Operating Temperature Range-25°C to 60°C
TypeSingle-phase inverter