for S6 Series Grid Inverter
Version 1.0, Release Date: 04,2023
Applicable models
S6-GR1P2.5K-S
S6-GR1P3K-S
S6-GR1P3.6K-S
S6-GR1P4K-S
S6-GR1P4.6K-S
S6-GR1P5K-S
S6-GR1P6K-S
Applicable System
Single phase system

Other manuals for SOLIS S6-GR1P6K

Questions and Answers

  • L
    Linda BarberSep 13, 2025
    What is 'LmtByVar' on my SOLIS Inverter and how do I handle it?
    • E
      Eric NguyenSep 13, 2025
      The 'LmtByVar' message on your SOLIS Inverter is triggered by local safety regulations when the grid voltage is high, activating Volt-watt working mode. Generally, this does not require intervention. However, if it's due to a factory test error, you can disable this mode via the LCD: Main menu ? Advanced Settings ? Password 0010 ? STD mode settings ? Working Mode ? Working mode: NULL ? Save and exit.
  • P
    Phillip KentSep 14, 2025
    What does 'LmtByEPM' mean on my SOLIS Inverter and how can I resolve it?
    • N
      Natasha YoungSep 14, 2025
      If your SOLIS Inverter displays 'LmtByEPM', confirm whether the inverter is connected to an external EPM/meter to prevent reverse current. Also, check if the inverter is controlled by an external third-party device and confirm whether the power setting of the inverter power control is limited. Verify settings in section 6.6.7 and check your meter readings.
  • N
    Nicole WhitakerSep 14, 2025
    What does 'DCInj-FAULT (1037 DATA:0000)' mean on my SOLIS S6-GR1P6K and how to resolve it?
    • M
      Michael LewisSep 14, 2025
      If your SOLIS Inverter displays 'DCInj-FAULT (1037 DATA:0000)', confirm that the grid is not abnormal and that the AC cable connection is normal. If the problem continues, restart the system.
  • M
    Mark JohnsonSep 14, 2025
    How to fix grid overvoltage on SOLIS Inverter?
    • M
      Miguel Luna DDSSep 15, 2025
      If your SOLIS Inverter is showing a grid overvoltage error, make sure the grid is correctly connected and then wait for the grid to return to normal operating levels.
  • D
    Denise HancockSep 15, 2025
    What to do if my SOLIS S6-GR1P6K shows grid undervoltage?
    • T
      thorntondeborahSep 15, 2025
      If your SOLIS Inverter displays a grid undervoltage error, verify the grid connection is correct and wait for the grid voltage to stabilize within the normal range.
  • E
    Ebony WarrenSep 15, 2025
    How do I resolve grid overfrequency on my SOLIS S6-GR1P6K?
    • G
      gmarshallSep 15, 2025
      In the event of a grid overfrequency error on your SOLIS Inverter, check the grid connection to ensure it is correct, and wait for the grid frequency to return to normal.
  • K
    kpriceSep 15, 2025
    What to do if SOLIS S6-GR1P6K Inverter says battery not connected?
    • R
      Ryan WagnerSep 15, 2025
      If the SOLIS Inverter displays that the battery is not connected, verify that the battery is correctly connected and that the battery contactor is not disconnected. Restart the battery after checking the connections.
  • M
    Mr. Jeffrey Summers IISep 15, 2025
    How to troubleshoot battery overvoltage on SOLIS Inverter?
    • S
      Sarah MillerSep 16, 2025
      If you are experiencing a battery overvoltage error with your SOLIS Inverter, check if the battery overvoltage setting is reasonable. Also, determine if the battery has reached its end of life.
  • D
    daniellecrawfordSep 16, 2025
    How to fix AC transient overcurrent on SOLIS S6-GR1P6K?
    • R
      Rodney RangelSep 16, 2025
      If your SOLIS Inverter is showing an AC transient overcurrent error, check if the backup port is shorted and restart the inverter.
  • R
    rzamoraSep 16, 2025
    What to do for bypass overload fault on SOLIS Inverter?
    • T
      Thomas StevensSep 16, 2025
      If your SOLIS Inverter is showing a bypass overload fault: 1. Check if the load of the backup port exceeds the rating output power. 2. Reduce the load of the backup port, and then restart the inverter.

SOLIS S6-GR1P6K Specifications

General IconGeneral
ModelS6-GR1P6K
Rated Output Power6000 W
Max. Input Voltage600 V
Start-up Voltage90 V
Number of MPPT Trackers2
MPPT Efficiency99.9%
Nominal AC Output Power6000 W
Nominal AC Voltage230 V
AC Voltage Range180-280 V
Nominal Grid Frequency50/60 Hz
THDi<3%
DC Connection TypeMC4
Protection DegreeIP65
TopologyTransformerless
Cooling MethodNatural convection
Max. DC Input Power9000 W
Max. AC Apparent Power6000 VA
Operating Temperature Range-25°C to 60°C
TypeSingle-phase inverter