SOLIS S6-GR1P6K - User Manual

SOLIS S6-GR1P6K
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
User Manual
for S6 Series Grid Inverter
Version 1.0, Release Date: 04,2023
Applicable models
S6-GR1P2.5K-S
S6-GR1P3K-S
S6-GR1P3.6K-S
S6-GR1P4K-S
S6-GR1P4.6K-S
S6-GR1P5K-S
S6-GR1P6K-S
Applicable System
Single phase system

Other manuals for SOLIS S6-GR1P6K

Questions and Answers

  • T
    Tabitha AndersonSep 8, 2025
    What causes UN-TEM error on a SOLIS S6-GR1P6K Inverter?
    • D
      Deborah HolmesSep 8, 2025
      If your SOLIS Inverter displays an UN-TEM error, check if the ambient temperature is too low and restart the inverter. If the error persists, contact the factory's customer service.
  • V
    Vanessa WilsonSep 8, 2025
    What to do if my SOLIS Inverter displays 'Over-Load'?
    • V
      victor71Sep 8, 2025
      If your SOLIS Inverter shows an 'Over-Load' error, it means the backup load power is too large, or an inductive load's startup power is too high. Try removing some of the backup load or disconnecting any inductive loads from the backup.
  • W
    Wendy StewartSep 8, 2025
    How to troubleshoot a 'Fan Alarm' on my SOLIS Inverter?
    • J
      Jenna AriasSep 8, 2025
      If you receive a 'Fan Alarm' on your SOLIS Inverter, check whether the internal fan is working correctly or if it is jammed.
  • S
    Samuel KellySep 8, 2025
    What does 'Off' mean on my SOLIS S6-GR1P6K and how to fix it?
    • M
      Michael RodriguezSep 9, 2025
      If your SOLIS Inverter is 'Off', turn on the device using the ON/OFF Setting.
  • M
    Michael LeonSep 9, 2025
    Why is my SOLIS Inverter showing 'OV-G-V01'?
    • S
      Scott FernandezSep 9, 2025
      The 'OV-G-V01' error on your SOLIS Inverter indicates a potential issue with the power grid or AC cable connection. First, check if the power grid is abnormal. Next, confirm that the AC cable is properly connected. If the issue persists, restart the system.
  • B
    Brittney GarciaSep 9, 2025
    What to do if my SOLIS S6-GR1P6K Inverter displays 'Surge Alarm'?
    • M
      Michael BryantSep 9, 2025
      If your SOLIS Inverter is showing a 'Surge Alarm', it indicates a grid side fault. Restart the device. If the problem continues, contact the manufacturer's customer service.
  • A
    Aaron WhiteSep 9, 2025
    How do I fix a 'CAN Fail' error on my SOLIS S6-GR1P6K Inverter?
    • S
      Sharon ShawSep 9, 2025
      To address a 'CAN Fail' error on your SOLIS Inverter: - Check the cable conditions. - Ensure the cable is plugged into the CAN port of both the battery and the inverter. - Verify you are using the correct cable. - Note that some batteries require a special cable from the battery manufacturer.
  • D
    Dawn WilsonSep 10, 2025
    What does 'OV-Vbatt' mean on my SOLIS S6-GR1P6K and how to solve it?
    • X
      xsalinasSep 10, 2025
      The 'OV-Vbatt' error on your SOLIS Inverter indicates an over-voltage issue with the battery. Verify the battery voltage is within the specified standards. Also, measure the battery voltage at the inverter connection point. If problems persist, contact your battery manufacturer for service.
  • A
    Alicia LewisSep 10, 2025
    What does 'OV-DC01 (1020 DATA:0001)' mean on SOLIS Inverter and how to fix it?
    • S
      Sharon MartinSep 10, 2025
      The error 'OV-DC01 (1020 DATA:0001)' on your SOLIS Inverter indicates an abnormal PV voltage. Check if the PV voltage is abnormal. If the issue persists, restart the system.
  • V
    velazquezmiguelSep 12, 2025
    What does 'OV-TEM (1032 DATA:0000)' mean on my SOLIS Inverter and how do I resolve it?
    • D
      David RichardsonSep 12, 2025
      If your SOLIS Inverter displays 'OV-TEM (1032 DATA:0000)', it indicates a temperature issue. Check whether the surrounding environment of the inverter has poor heat dissipation and confirm whether the product installation meets the requirements.

SOLIS S6-GR1P6K Specifications

General IconGeneral
ModelS6-GR1P6K
Rated Output Power6000 W
Max. Input Voltage600 V
Start-up Voltage90 V
Number of MPPT Trackers2
MPPT Efficiency99.9%
Nominal AC Output Power6000 W
Nominal AC Voltage230 V
AC Voltage Range180-280 V
Nominal Grid Frequency50/60 Hz
THDi<3%
DC Connection TypeMC4
Protection DegreeIP65
TopologyTransformerless
Cooling MethodNatural convection
Max. DC Input Power9000 W
Max. AC Apparent Power6000 VA
Operating Temperature Range-25°C to 60°C
TypeSingle-phase inverter