EasyManua.ls Logo

SOLIS S6-GR1P6K - User Manual

SOLIS S6-GR1P6K
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
User Manual
for S6 Series Grid Inverter
Version 1.0, Release Date: 04,2023
Applicable models
S6-GR1P2.5K-S
S6-GR1P3K-S
S6-GR1P3.6K-S
S6-GR1P4K-S
S6-GR1P4.6K-S
S6-GR1P5K-S
S6-GR1P6K-S
Applicable System
Single phase system

Other manuals for SOLIS S6-GR1P6K

Questions and Answers

  • A
    Alex SchwartzSep 18, 2025
    What to do if SOLIS S6-GR1P6K Inverter shows over DC injection error?
    • A
      Anna Reyes DDSSep 18, 2025
      If your SOLIS Inverter is showing an over DC injection error, restart the inverter.
  • C
    codystewartSep 12, 2025
    What does 'OV-Vbackup' mean on my SOLIS S6-GR1P6K Inverter and how to fix it?
    • D
      Destiny PollardSep 12, 2025
      The 'OV-Vbackup' error on your SOLIS Inverter indicates an over-voltage issue with the backup. Check whether the backup port wiring is normal. If the issue persists, restart the system.
  • V
    velazquezmiguelSep 12, 2025
    What does 'OV-TEM (1032 DATA:0000)' mean on my SOLIS Inverter and how do I resolve it?
    • D
      David RichardsonSep 12, 2025
      If your SOLIS Inverter displays 'OV-TEM (1032 DATA:0000)', it indicates a temperature issue. Check whether the surrounding environment of the inverter has poor heat dissipation and confirm whether the product installation meets the requirements.
  • K
    kyle83Aug 29, 2025
    What does LmtByEPM mean on my SOLIS S6-GR1P6K?
    • M
      Michael RyanAug 29, 2025
      If your SOLIS Inverter is showing 'LmtByEPM', confirm the inverter is connected to an external EPM/meter to prevent reverse current. Also, check if the inverter is controlled by an external third-party device and verify if the power setting of the inverter power control is limited. You may also need to verify settings in section 6.6.7 and check your meter readings.
  • L
    Loretta BishopAug 29, 2025
    What does 12Power-FAULT mean on SOLIS S6-GR1P6K Inverter?
    • H
      Herbert DelacruzAug 29, 2025
      If your SOLIS Inverter displays '12Power-FAULT (1038 DATA:0000)', check for current leakage to ground, verify your grounding, and ensure all wires are in good condition and not leaking current to ground.
  • U
    uandersonAug 29, 2025
    What does BatName-FAIL mean on SOLIS Inverter?
    • S
      sstephensAug 30, 2025
      If your SOLIS Inverter displays 'BatName-FAIL', confirm that the battery model selection is consistent with the actual battery you are using.
  • C
    Cynthia GuerraAug 30, 2025
    What does Fan Alarm mean on SOLIS Inverter?
    • O
      olopezAug 30, 2025
      If your SOLIS Inverter displays 'Fan Alarm', check if the internal fan is working correctly or if it is jammed.
  • P
    porteralexisSep 23, 2025
    What to do if my SOLIS S6-GR1P6K Inverter displays ARC- FAULT (1041 DATA:0000)?
    • R
      Ryan JohnsonSep 23, 2025
      If your SOLIS Inverter shows the ARC- FAULT (1041 DATA:0000) error, verify that all connections within your PV system are tight. If further adjustments are necessary, arc fault settings can be changed in the advanced settings.
  • K
    kpriceSep 15, 2025
    What to do if SOLIS S6-GR1P6K Inverter says battery not connected?
    • R
      Ryan WagnerSep 15, 2025
      If the SOLIS Inverter displays that the battery is not connected, verify that the battery is correctly connected and that the battery contactor is not disconnected. Restart the battery after checking the connections.
  • C
    Christian LopezSep 12, 2025
    What does 'BatName-FAIL' mean on my SOLIS Inverter and how to resolve it?
    • M
      Melissa WilsonSep 12, 2025
      If your SOLIS Inverter displays 'BatName-FAIL', confirm whether the battery model selection is consistent with the actual one.

SOLIS S6-GR1P6K Specifications

General IconGeneral
ModelS6-GR1P6K
Rated Output Power6000 W
Max. Input Voltage600 V
Start-up Voltage90 V
Number of MPPT Trackers2
MPPT Efficiency99.9%
Nominal AC Output Power6000 W
Nominal AC Voltage230 V
AC Voltage Range180-280 V
Nominal Grid Frequency50/60 Hz
THDi<3%
DC Connection TypeMC4
Protection DegreeIP65
TopologyTransformerless
Cooling MethodNatural convection
Max. DC Input Power9000 W
Max. AC Apparent Power6000 VA
Operating Temperature Range-25°C to 60°C
TypeSingle-phase inverter