User Manual
for S6 Series Grid Inverter
Version 1.0, Release Date: 04,2023
Applicable models
S6-GR1P2.5K-S
S6-GR1P3K-S
S6-GR1P3.6K-S
S6-GR1P4K-S
S6-GR1P4.6K-S
S6-GR1P5K-S
S6-GR1P6K-S
Applicable System
Single phase system

Other manuals for SOLIS S6-GR1P6K

Questions and Answers

  • B
    Brent ChenSep 22, 2025
    Why is my SOLIS Inverter showing OV-ILLC (1052 DATA:0000) error?
    • E
      Elizabeth SmithSep 22, 2025
      The OV-ILLC (1052 DATA:0000) error on your SOLIS Inverter may indicate that the backup load is overloaded. Check whether the backup load is overloaded. If the issue persists, restart the system.
  • J
    Jesus ColeAug 31, 2025
    What should I do if my SOLIS S6-GR1P6K shows UN-Vbatt?
    • D
      dawn99Aug 31, 2025
      If your SOLIS Inverter displays UN-Vbatt, restart the system to see if the fault clears. If the issue persists, it's recommended to contact the manufacturer's customer service for further assistance.
  • N
    Nicole JohnsonAug 27, 2025
    What to do if SOLIS Inverter displays OV-ILLC (1052 DATA:0000)?
    • P
      Paige FisherAug 27, 2025
      If your SOLIS Inverter displays OV-ILLC (1052 DATA:0000), it may be due to an overloaded backup load. Check whether the backup load is overloaded. If the problem continues, restart the system to see if the fault clears.
  • H
    Heather GrahamSep 23, 2025
    What does Grid disturbance 02 mean on SOLIS S6-GR1P6K?
    • C
      Carla McdanielSep 23, 2025
      A 'Grid disturbance 02' error on your SOLIS Inverter suggests a problem with the power grid or AC cable connection. Check if the grid is seriously distorted and ensure the AC cable is reliably connected.
  • P
    porteralexisSep 23, 2025
    What to do if my SOLIS S6-GR1P6K Inverter displays ARC- FAULT (1041 DATA:0000)?
    • R
      Ryan JohnsonSep 23, 2025
      If your SOLIS Inverter shows the ARC- FAULT (1041 DATA:0000) error, verify that all connections within your PV system are tight. If further adjustments are necessary, arc fault settings can be changed in the advanced settings.
  • M
    Maxwell BakerSep 3, 2025
    What does UN-TEM (103A DATA:0000) error mean on my SOLIS S6-GR1P6K Inverter?
    • L
      Logan HaleySep 3, 2025
      If your SOLIS Inverter displays UN-TEM (103A DATA:0000), check the working environment temperature of the inverter. Restart the system to confirm if the fault continues.
  • L
    Lori HopkinsSep 5, 2025
    How to troubleshoot OV-TEM error on SOLIS Inverter?
    • R
      Raymond ChandlerSep 5, 2025
      If your SOLIS Inverter is showing an OV-TEM error, start by checking if the installation location meets the requirements specified in the user manual. Then, try to lower the ambient temperature around the inverter. After doing so, restart the inverter after fifteen minutes. If the error continues, contact the factory's customer service.
  • D
    Dawn WilsonSep 10, 2025
    What does 'OV-Vbatt' mean on my SOLIS S6-GR1P6K and how to solve it?
    • X
      xsalinasSep 10, 2025
      The 'OV-Vbatt' error on your SOLIS Inverter indicates an over-voltage issue with the battery. Verify the battery voltage is within the specified standards. Also, measure the battery voltage at the inverter connection point. If problems persist, contact your battery manufacturer for service.
  • T
    tonywigginsSep 17, 2025
    How to troubleshoot battery overcurrent on SOLIS S6-GR1P6K Inverter?
    • J
      Jessica BenitezSep 18, 2025
      If your SOLIS Inverter is showing a battery overcurrent error, restart the inverter.
  • K
    kyle99Aug 25, 2025
    What to do if my SOLIS S6-GR1P6K Inverter displays GRID-INTF02 (1046 DATA:0000)?
    • R
      Ryan HawkinsAug 25, 2025
      If your SOLIS Inverter displays GRID-INTF02 (1046 DATA:0000), confirm whether the grid is seriously distorted and check whether the AC cable is connected reliably.

SOLIS S6-GR1P6K Specifications

General IconGeneral
ModelS6-GR1P6K
Rated Output Power6000 W
Max. Input Voltage600 V
Start-up Voltage90 V
Number of MPPT Trackers2
MPPT Efficiency99.9%
Nominal AC Output Power6000 W
Nominal AC Voltage230 V
AC Voltage Range180-280 V
Nominal Grid Frequency50/60 Hz
THDi<3%
DC Connection TypeMC4
Protection DegreeIP65
TopologyTransformerless
Cooling MethodNatural convection
Max. DC Input Power9000 W
Max. AC Apparent Power6000 VA
Operating Temperature Range-25°C to 60°C
TypeSingle-phase inverter