SOLIS S6-EH3P5K-H - User Manual

SOLIS S6-EH3P5K-H
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
User Manual
for S6 Series Hybrid Inverter
Version 1.2, Release Date: 04,2023
Applicable models
S6-EH3P5K2-H
S6-EH3P6K2-H
S6-EH3P8K2-H
S6-EH3P10K2-H
S6-EH3P3K-H-EU
S6-EH3P4K-H-EU
S6-EH3P5K-H-EU
S6-EH3P6K-H-EU
S6-EH3P8K-H-EU
S6-EH3P10K-H-EU
S6-EH3P10K-H-EU-BE
Applicable System
Three phase system

Other manuals for SOLIS S6-EH3P5K-H

Questions and Answers

  • D
    Denise MorenoAug 31, 2025
    What should I do if my SOLIS S6-EH3P5K-H Inverter shows UN-Vbatt?
    • A
      ashleylongAug 31, 2025
      If your SOLIS Inverter displays UN-Vbatt, restart the system to see if the fault clears. If the issue persists, it's recommended to contact the manufacturer's customer service for further assistance.
  • D
    David ThomasAug 25, 2025
    Why does my SOLIS Inverter show NO-Battery, and how do I fix it?
    • D
      David ShawAug 25, 2025
      If your SOLIS Inverter shows NO-Battery, check the information page to verify that the battery voltage is within the specified standards. Also, measure the battery voltage at the plug.
  • J
    Joshua BlakeSep 23, 2025
    What does Grid disturbance 02 mean on SOLIS Inverter?
    • W
      William ShepherdSep 23, 2025
      A 'Grid disturbance 02' error on your SOLIS Inverter suggests a problem with the power grid or AC cable connection. Check if the grid is seriously distorted and ensure the AC cable is reliably connected.
  • A
    Antonio SullivanSep 5, 2025
    How to troubleshoot OV-TEM error on SOLIS S6-EH3P5K-H?
    • S
      Stephen MartinezSep 5, 2025
      If your SOLIS Inverter is showing an OV-TEM error, start by checking if the installation location meets the requirements specified in the user manual. Then, try to lower the ambient temperature around the inverter. After doing so, restart the inverter after fifteen minutes. If the error continues, contact the factory's customer service.
  • J
    Jessica MyersSep 10, 2025
    What does 'OV-Vbatt' mean on my SOLIS Inverter and how to solve it?
    • S
      Steven DavisSep 10, 2025
      The 'OV-Vbatt' error on your SOLIS Inverter indicates an over-voltage issue with the battery. Verify the battery voltage is within the specified standards. Also, measure the battery voltage at the inverter connection point. If problems persist, contact your battery manufacturer for service.
  • S
    Stacy GomezSep 3, 2025
    What does UN-TEM (103A DATA:0000) error mean on my SOLIS Inverter?
    • E
      Eileen RossSep 3, 2025
      If your SOLIS Inverter displays UN-TEM (103A DATA:0000), check the working environment temperature of the inverter. Restart the system to confirm if the fault continues.
  • M
    Meagan DavisAug 29, 2025
    What does LmtByEPM mean on my SOLIS Inverter?
    • J
      Jim ChavezAug 29, 2025
      If your SOLIS Inverter is showing 'LmtByEPM', confirm the inverter is connected to an external EPM/meter to prevent reverse current. Also, check if the inverter is controlled by an external third-party device and verify if the power setting of the inverter power control is limited. You may also need to verify settings in section 6.6.7 and check your meter readings.
  • K
    Keith HickmanSep 12, 2025
    What does 'BatName-FAIL' mean on my SOLIS S6-EH3P5K-H and how to resolve it?
    • M
      mahoneyjackieSep 12, 2025
      If your SOLIS Inverter displays 'BatName-FAIL', confirm whether the battery model selection is consistent with the actual one.
  • B
    Billy LewisSep 7, 2025
    How to fix ILeak-Check error on SOLIS Inverter?
    • C
      Cynthia HollowaySep 7, 2025
      If your SOLIS Inverter shows an ILeak-Check error, upgrade the software to the latest version. If the fault continues after the upgrade, contact the factory's customer service.
  • L
    lwatkinsAug 27, 2025
    What to do if SOLIS Inverter displays OV-ILLC (1052 DATA:0000)?
    • Y
      ymckayAug 27, 2025
      If your SOLIS Inverter displays OV-ILLC (1052 DATA:0000), it may be due to an overloaded backup load. Check whether the backup load is overloaded. If the problem continues, restart the system to see if the fault clears.

SOLIS S6-EH3P5K-H Specifications

General IconGeneral
ModelS6-EH3P5K-H
TypeHybrid Inverter
Max. Input Voltage600 V
Number of MPPTs2
AC Voltage Range180-280V
THDi<3%
Nominal Grid Frequency50/60Hz
MPPT Efficiency99.9%
DC SwitchYes
Protection DegreeIP65
Protection ClassI
Operating Temperature Range-25°C to +60°C
Cooling MethodNatural Convection
Rated Power5000 W
Max. DC Input Power7500 W
Rated AC Output Power5000 W
Max. AC Apparent Power5500 VA
Nominal AC Voltage230 V
Power Factor0.8 leading to 0.8 lagging
Grid Frequency Range45 Hz - 55 Hz / 55 Hz - 65 Hz
CommunicationRS485