What does BatName-FAIL mean on SOLIS S6-EH3P5K-H?
- WWilliam SchultzAug 29, 2025
If your SOLIS Inverter displays 'BatName-FAIL', confirm that the battery model selection is consistent with the actual battery you are using.

What does BatName-FAIL mean on SOLIS S6-EH3P5K-H?
If your SOLIS Inverter displays 'BatName-FAIL', confirm that the battery model selection is consistent with the actual battery you are using.
What does Fan Alarm mean on SOLIS Inverter?
If your SOLIS Inverter displays 'Fan Alarm', check if the internal fan is working correctly or if it is jammed.
What to do if my SOLIS S6-EH3P5K-H Inverter shows OV-G-V01 error?
If your SOLIS Inverter displays OV-G-V01 error, ensure the power grid is working normally and the AC cable is properly connected. If the issue continues after these checks, restart the system to see if the fault clears.
What does OV-Vbatt mean on my SOLIS Inverter?
The OV-Vbatt error on your SOLIS Inverter indicates an over-voltage issue with the battery. Verify the battery voltage is within the specified standards. Measure the battery voltage at the inverter connection point. If the problem continues, contact your battery manufacturer.
Why is my SOLIS S6-EH3P5K-H showing OV-TEM (1032 DATA:0000) error?
The OV-TEM (1032 DATA:0000) error on your SOLIS Inverter could be due to poor heat dissipation around the inverter or improper installation. Check if the surrounding environment allows for adequate heat dissipation and ensure the product installation meets the requirements.
What does 'OV-Vbackup' mean on my SOLIS S6-EH3P5K-H Inverter and how to fix it?
The 'OV-Vbackup' error on your SOLIS Inverter indicates an over-voltage issue with the backup. Check whether the backup port wiring is normal. If the issue persists, restart the system.
What should I do if my SOLIS S6-EH3P5K-H Inverter shows UN-Vbatt?
If your SOLIS Inverter displays UN-Vbatt, restart the system to see if the fault clears. If the issue persists, it's recommended to contact the manufacturer's customer service for further assistance.
How to fix BatName-FAIL error on SOLIS S6-EH3P5K-H?
If your SOLIS Inverter shows BatName-FAIL, confirm that the battery model selection in the settings is consistent with the actual battery model connected.
What does Fan Alarm mean on my SOLIS S6-EH3P5K-H, and how can I fix it?
If your SOLIS Inverter displays Fan Alarm, check to see if the internal fan is working correctly or if it is jammed.
What to do if my SOLIS Inverter displays OV-DC01 (1020 DATA:0001) error?
If your SOLIS Inverter displays OV-DC01 (1020 DATA:0001), check if the PV voltage is abnormal. Restart the system and confirm if the fault continues.
| Model | S6-EH3P5K-H |
|---|---|
| Type | Hybrid Inverter |
| Max. Input Voltage | 600 V |
| Number of MPPTs | 2 |
| AC Voltage Range | 180-280V |
| THDi | <3% |
| Nominal Grid Frequency | 50/60Hz |
| MPPT Efficiency | 99.9% |
| DC Switch | Yes |
| Protection Degree | IP65 |
| Protection Class | I |
| Operating Temperature Range | -25°C to +60°C |
| Cooling Method | Natural Convection |
| Rated Power | 5000 W |
| Max. DC Input Power | 7500 W |
| Rated AC Output Power | 5000 W |
| Max. AC Apparent Power | 5500 VA |
| Nominal AC Voltage | 230 V |
| Power Factor | 0.8 leading to 0.8 lagging |
| Grid Frequency Range | 45 Hz - 55 Hz / 55 Hz - 65 Hz |
| Communication | RS485 |