What is 'LmtByVar' on my SOLIS S6-EH3P5K-H Inverter and how do I handle it?
- MMichael RobinsonSep 14, 2025
The 'LmtByVar' message on your SOLIS Inverter is triggered by local safety regulations when the grid voltage is high, activating Volt-watt working mode. Generally, this does not require intervention. However, if it's due to a factory test error, you can disable this mode via the LCD: Main menu ? Advanced Settings ? Password 0010 ? STD mode settings ? Working Mode ? Working mode: NULL ? Save and exit.