J
Julie DavenportSep 22, 2025
How to resolve Slave DSP Check Error on SOLIS Inverter?
- MMonica ChangSep 22, 2025
If your SOLIS Inverter is showing a Slave DSP Check Error, restart the inverter.

How to resolve Slave DSP Check Error on SOLIS Inverter?
If your SOLIS Inverter is showing a Slave DSP Check Error, restart the inverter.
What should I do if my SOLIS S6-EH3P5K-H Inverter shows UN-Vbatt?
If your SOLIS Inverter displays UN-Vbatt, restart the system to see if the fault clears. If the issue persists, it's recommended to contact the manufacturer's customer service for further assistance.
What to do if SOLIS Inverter displays OV-ILLC (1052 DATA:0000)?
If your SOLIS Inverter displays OV-ILLC (1052 DATA:0000), it may be due to an overloaded backup load. Check whether the backup load is overloaded. If the problem continues, restart the system to see if the fault clears.
What does Grid disturbance 02 mean on SOLIS Inverter?
A 'Grid disturbance 02' error on your SOLIS Inverter suggests a problem with the power grid or AC cable connection. Check if the grid is seriously distorted and ensure the AC cable is reliably connected.
What to do if my SOLIS S6-EH3P5K-H displays ARC- FAULT (1041 DATA:0000)?
If your SOLIS Inverter shows the ARC- FAULT (1041 DATA:0000) error, verify that all connections within your PV system are tight. If further adjustments are necessary, arc fault settings can be changed in the advanced settings.
What does UN-TEM (103A DATA:0000) error mean on my SOLIS Inverter?
If your SOLIS Inverter displays UN-TEM (103A DATA:0000), check the working environment temperature of the inverter. Restart the system to confirm if the fault continues.
How to troubleshoot OV-TEM error on SOLIS S6-EH3P5K-H?
If your SOLIS Inverter is showing an OV-TEM error, start by checking if the installation location meets the requirements specified in the user manual. Then, try to lower the ambient temperature around the inverter. After doing so, restart the inverter after fifteen minutes. If the error continues, contact the factory's customer service.
What does 'OV-Vbatt' mean on my SOLIS Inverter and how to solve it?
The 'OV-Vbatt' error on your SOLIS Inverter indicates an over-voltage issue with the battery. Verify the battery voltage is within the specified standards. Also, measure the battery voltage at the inverter connection point. If problems persist, contact your battery manufacturer for service.
How to troubleshoot battery overcurrent on SOLIS S6-EH3P5K-H Inverter?
If your SOLIS Inverter is showing a battery overcurrent error, restart the inverter.
What to do if my SOLIS S6-EH3P5K-H displays GRID-INTF02 (1046 DATA:0000)?
If your SOLIS Inverter displays GRID-INTF02 (1046 DATA:0000), confirm whether the grid is seriously distorted and check whether the AC cable is connected reliably.
| Model | S6-EH3P5K-H |
|---|---|
| Type | Hybrid Inverter |
| Max. Input Voltage | 600 V |
| Number of MPPTs | 2 |
| AC Voltage Range | 180-280V |
| THDi | <3% |
| Nominal Grid Frequency | 50/60Hz |
| MPPT Efficiency | 99.9% |
| DC Switch | Yes |
| Protection Degree | IP65 |
| Protection Class | I |
| Operating Temperature Range | -25°C to +60°C |
| Cooling Method | Natural Convection |
| Rated Power | 5000 W |
| Max. DC Input Power | 7500 W |
| Rated AC Output Power | 5000 W |
| Max. AC Apparent Power | 5500 VA |
| Nominal AC Voltage | 230 V |
| Power Factor | 0.8 leading to 0.8 lagging |
| Grid Frequency Range | 45 Hz - 55 Hz / 55 Hz - 65 Hz |
| Communication | RS485 |












Loading...