User Manual
for S6 Series Grid Inverter
Version 1.0, Release Date: 04,2023
Applicable models
S6-GR1P2.5K-S
S6-GR1P3K-S
S6-GR1P3.6K-S
S6-GR1P4K-S
S6-GR1P4.6K-S
S6-GR1P5K-S
S6-GR1P6K-S
Applicable System
Single phase system

Other manuals for SOLIS S6-GR1P6K

Questions and Answers

  • N
    Nicole JohnsonAug 27, 2025
    What to do if SOLIS Inverter displays OV-ILLC (1052 DATA:0000)?
    • P
      Paige FisherAug 27, 2025
      If your SOLIS Inverter displays OV-ILLC (1052 DATA:0000), it may be due to an overloaded backup load. Check whether the backup load is overloaded. If the problem continues, restart the system to see if the fault clears.
  • D
    Dawn WilsonSep 10, 2025
    What does 'OV-Vbatt' mean on my SOLIS S6-GR1P6K and how to solve it?
    • X
      xsalinasSep 10, 2025
      The 'OV-Vbatt' error on your SOLIS Inverter indicates an over-voltage issue with the battery. Verify the battery voltage is within the specified standards. Also, measure the battery voltage at the inverter connection point. If problems persist, contact your battery manufacturer for service.
  • E
    Emily PerkinsAug 27, 2025
    What does ARC- FAULT (1041 DATA:0000) mean on SOLIS Inverter and how to fix it?
    • X
      xmontgomeryAug 27, 2025
      The ARC- FAULT (1041 DATA:0000) error on your SOLIS Inverter indicates a potential arc fault. Start by verifying that all connections within your PV system are tight. If further adjustment is needed, arc fault settings can be changed in advanced settings.
  • H
    Heather GrahamSep 23, 2025
    What does Grid disturbance 02 mean on SOLIS S6-GR1P6K?
    • C
      Carla McdanielSep 23, 2025
      A 'Grid disturbance 02' error on your SOLIS Inverter suggests a problem with the power grid or AC cable connection. Check if the grid is seriously distorted and ensure the AC cable is reliably connected.
  • A
    Alex SchwartzSep 18, 2025
    What to do if SOLIS S6-GR1P6K Inverter shows over DC injection error?
    • A
      Anna Reyes DDSSep 18, 2025
      If your SOLIS Inverter is showing an over DC injection error, restart the inverter.
  • C
    codystewartSep 12, 2025
    What does 'OV-Vbackup' mean on my SOLIS S6-GR1P6K Inverter and how to fix it?
    • D
      Destiny PollardSep 12, 2025
      The 'OV-Vbackup' error on your SOLIS Inverter indicates an over-voltage issue with the backup. Check whether the backup port wiring is normal. If the issue persists, restart the system.
  • C
    cheryl52Sep 22, 2025
    What to do if my SOLIS S6-GR1P6K displays Fan Alarm?
    • S
      Stephanie AlexanderSep 22, 2025
      If your SOLIS Inverter shows a Fan Alarm, check if the internal fan is working correctly or if it is jammed.
  • K
    Kristy WalkerSep 23, 2025
    What does OV-Vbatt mean on my SOLIS S6-GR1P6K?
    • G
      Gary RobersonSep 23, 2025
      The OV-Vbatt error on your SOLIS Inverter indicates an over-voltage issue with the battery. Verify the battery voltage is within the specified standards. Measure the battery voltage at the inverter connection point. If the problem continues, contact your battery manufacturer.
  • K
    kyle83Aug 29, 2025
    What does LmtByEPM mean on my SOLIS S6-GR1P6K?
    • M
      Michael RyanAug 29, 2025
      If your SOLIS Inverter is showing 'LmtByEPM', confirm the inverter is connected to an external EPM/meter to prevent reverse current. Also, check if the inverter is controlled by an external third-party device and verify if the power setting of the inverter power control is limited. You may also need to verify settings in section 6.6.7 and check your meter readings.
  • L
    Loretta BishopAug 29, 2025
    What does 12Power-FAULT mean on SOLIS S6-GR1P6K Inverter?
    • H
      Herbert DelacruzAug 29, 2025
      If your SOLIS Inverter displays '12Power-FAULT (1038 DATA:0000)', check for current leakage to ground, verify your grounding, and ensure all wires are in good condition and not leaking current to ground.

SOLIS S6-GR1P6K Specifications

General IconGeneral
ModelS6-GR1P6K
Rated Output Power6000 W
Max. Input Voltage600 V
Start-up Voltage90 V
Number of MPPT Trackers2
MPPT Efficiency99.9%
Nominal AC Output Power6000 W
Nominal AC Voltage230 V
AC Voltage Range180-280 V
Nominal Grid Frequency50/60 Hz
THDi<3%
DC Connection TypeMC4
Protection DegreeIP65
TopologyTransformerless
Cooling MethodNatural convection
Max. DC Input Power9000 W
Max. AC Apparent Power6000 VA
Operating Temperature Range-25°C to 60°C
TypeSingle-phase inverter