Read the installation guide carefully; professional installation required; check compatibility; follow standards.
Never immerse motor in liquid, avoid impacts, do not drop, do not drill motor, loop power cable.
Fitting the crown and drive wheel, measuring the motor head to drive wheel length.
Cutting, deburring the roller tube, and notching for smooth roller tubes.
Sliding motor into tube, securing tube to drive wheel with screws or rivets.
Attaching the assembly to end and motor brackets, fitting the stop ring.
Connecting the motor to the mains power supply according to the provided table.
Switching on power and pressing Up/Down buttons to program the control point.
Checking and adjusting the motor's rotation direction using the RTS control point.
Procedure for setting upper and lower limits based on roller shutter configuration.
Automatic adjustment for roller shutters with bolts and stops on the end slat.
Manual adjustment for the upper end limit when using bolts without end slat stops.
Manual adjustment for the lower end limit with flexible connections and end slat stops.
Manual adjustment for both lower and upper end limits with flexible connections and no stops.
Verifying the programmed upper and lower end limits using the RTS control point.
Definition and activation of the pre-programmed favourite position for the roller shutter.
Adjusting the roller shutter to a new favourite position and programming it.
Procedure to remove the previously set favourite position from the motor.
Steps to add or remove RTS and RT control points from the motor.
Procedure to program or delete RTS sensors, enabling them for use.
Adjusting and modifying end limits based on roller shutter connection type.
End limits are automatically adjusted; no modification needed for this configuration.
Procedure to modify the upper end limit with bolts but no end slat stops.
Procedure to modify the lower end limit with flexible connections and end slat stops.
Procedure to modify both lower and upper end limits with flexible connections and no stops.
How to change the motor's rotation direction at any time.
Details on standard functions like favourite position, stop, obstacle detection, and anti-freeze.
Procedure to activate the pre-programmed favourite position.
How to recall the favourite position using the STOP/my button.
How to stop the roller shutter movement using the STOP/my button.
Explanation of automatic obstacle detection for roller shutters fitted with bolts.
How the anti-freeze protection prevents damage to the roller shutter.
How the motor operates when linked to a Sunis RTS sensor.
How the motor reacts when sunlight reaches the sensor threshold.
How the motor reacts when sunlight level drops below the sensor threshold.
Table of common problems, their possible causes, and solutions for the Oximo RTS motor.
Procedure to reset all programmed control points, sensors, and favourite positions.
Procedure to replace a control point, including resetting and reprogramming.