28
Instruction for Use | HCA 56x and 8x8
6.3 Rolling Display
The EHCA 565, 566, 868 and 878 also feature the possibility of a rolling display 24h/24h.
With the software Prog6, Superprog or Tools Supercom (566), it is possible to individualize the
rolling display.
Up to 15 parameters can be chosen optionally from the list below. These parameters can be com-
bined in any order and are then shown on the rolling display.
Consumption value.
Time.
Date.
Set Day.
Set Day value.
Monthly values.
Half monthly values.
Radiator temperature.
Ambient temperature.
Identification number.
Maximum radiator temperature of the previous heating period.
Maximum radiator temperature of the current heating period.
18 monthly values for the maximum radiator temperature.
Error code.
Manipulation protection: storing of the duration of the last manipulation with date and the
accumulated duration of all manipulations in minutes.
Fraud Counter.
Segment test.
Software version.
Running hours.
Commissioning date.
Measuring principle, single sensor device with start sensor or double sensor device.
Short or long telegram for radio wM-Bus.
The duration of the display of the values can be chosen individually between 1 - 30 seconds.
Example:
Order and duration of display
Pos. 0 : Error (parameter ex factory, cannot be changed) [5 s]
(only displayed in case of an error message)
Pos 1 : Time [1 s]
Pos 2 : Segment test [5 s]
Pos 3 : Consumption value [10 s]
Pos 4 : Set Day [1 s]
Pos 5 : Set Day value [8 s]
Pos 6 : Monthly value [5 s]
Pos 7 : Blank (therefore no display).
Pos 8 – Pos 15 : Blank (therefore no display. It is not necessary to occupy all positions).
The rolling display can also be deactivated by the Prog6, i.e. the device operates as in standard
menu mode except that only these values and the values of the corresponding sub-menus that
have been defined in the rolling menu can be displayed by pushing the button. After 2 minutes
during which the button has not been pushed, the display goes out.