SYSTEM SETUP
2-8. CCP-8000 Panel Cabling
How to Connect the Cables
Parts required
. 50-pin cable supplied with the center control panel
. 50-pin cable supplied with the MKS-8075
. USB cable (5 m) supplied with the center control panel
Connecting cables for the MKS-8075
1. Connect the EXT PANEL 1 to 3 terminals of the
system control unit MKS-8010 to the SCU IN termi-
nals of the MKS-8075 using the 50-pin cable supplied
with the center control panel.
2. Connect the SCU OUT terminal of the MKS-8075 to
the SCU IN terminal of the adjacent MKS-8075 using
the cable supplied with the MKS-8075 as shown in the
illustration.
Connecting cables for the MKS-8076
Connect the DEVICE terminal of the system control unit
MKS-8010 to the IN terminal of the MKS-8076 using the
USB cable supplied with the center control panel.
MKS-8076
50-pin cable supplied
with the MKS-8025
USB cable supplied with
the center control panel
O
U
T
O
U
T
O
U
T
O
U
T
O
U
T
O
U
T
50-pin cable supplied with
the center control panel
MKS-8075
MKS-8075
MKS-8075
IN
IN
IN
IN
IN