CFD-G550CP
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450 kHz
AM FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display 530 kHz 1,710 kHz
Reading on Digital voltmeter 1.0 ± 0.05 V 5.3 ± 0.7 V
Adjustment Part L4 <confirmation>
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3 CT3
620 kHz 1,400 kHz
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
10.7 MHz
FM FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display 87.5 MHz 108 MHz
Reading on Digital voltmeter 1.3 ± 0.3 V 3.0 ± 0.2 V
Adjustment Part <confirmation> L2
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1 CT1
87.5 MHz 108 MHz
digital
voltmeter
100 k
TP (VT)
i
jack (J391)
set
32
level meter
(range: 0.5–5 V ac
)
Put the lead-wire
antenna close to
the set.
AM RF signal
generator
TP (FM IN)
FM RF signal
generator
0.01
µ
F
set
TUNER SECTION 0 dB = 1 µV
AM Section
Setting:
RADIO BAND•AUTO PRESET button: AM
30% amplitude
modulation by
400 Hz signal
FM Section
Setting:
RADIO BAND•AUTO PRESET button: FM
75 kHz frequency
deviation by 1 kHz signal
output level : as low as possible
Connecting Level Meter (FM and AM)
Adjustment Location: See page 18.
Connecting Digital Voltmeter (FM and AM)
•Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.